← Texas

Tap water quality report

Central Wcid of Angelina County

EPA monitoring tested this supplier for 109 contaminants and detected 26. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

109
contaminants tested
26
detected
7,381
people served
18
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Angelina

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

18
health-based violations
34
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2013-10-01 → 2013-12-31
MCL Health-based Resolved 2013-10-01 → 2013-12-31
MCL Health-based Resolved 2013-07-01 → 2013-09-30
MCL Health-based Resolved 2013-07-01 → 2013-09-30
MCL Health-based Resolved 2013-07-01 → 2013-09-30
MCL Health-based Resolved 2013-07-01 → 2013-09-30
MCL Health-based Resolved 2013-07-01 → 2013-09-30
MCL Health-based Resolved 2013-07-01 → 2013-09-30
MCL Health-based Resolved 2013-04-01 → 2013-06-30
MCL Health-based Resolved 2013-04-01 → 2013-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
22.615 µg/L
No EPA limit set
worst single sample: 31.6 µg/L
58/58 SYR4 2012–2019
Dibromochloromethane
17.695 µg/L
No EPA limit set
worst single sample: 25.1 µg/L
58/58 SYR4 2012–2019
Chloroform
38.02 µg/L
No EPA limit set
worst single sample: 49 µg/L
57/58 SYR4 2012–2019
Dichloroacetic Acid
15.535 µg/L
No EPA limit set
worst single sample: 18.3 µg/L
54/54 SYR4 2012–2019
TTHM
72.955 µg/L 91%
of the EPA limit 80 µg/L
worst single sample: 96.5 µg/L
54/54 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
29.085 µg/L 48%
of the EPA limit 60 µg/L
worst single sample: 30.6 µg/L
54/54 SYR4 2012–2019
Trichloroacetic Acid
8.635 µg/L
No EPA limit set
worst single sample: 10.1 µg/L
54/54 SYR4 2012–2019
Copper
119.5 µg/L 9.2%
of the EPA limit 1300 µg/L
worst single sample: 146 µg/L
51/58 SYR4 2013–2017
Dibromoacetic Acid
3.795 µg/L
No EPA limit set
worst single sample: 5.9 µg/L
42/54 SYR4 2012–2019
Bromoform
7.94 µg/L
No EPA limit set
worst single sample: 11.6 µg/L
36/58 SYR4 2012–2019
Nitrate
100.7 µg/L 1%
of the EPA limit 10000 µg/L
worst single sample: 104 µg/L
32/32 SYR4 2012–2019
Monochloroacetic Acid
2.235 µg/L
No EPA limit set
worst single sample: 2.3 µg/L
14/54 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
13/13 LCR 2023
Lead
2.553 µg/L 17%
of the EPA limit 15 µg/L
worst single sample: 2.7 µg/L
7/58 SYR4 2013–2017
Asbestos
16.6747 MFL 238%
of the EPA limit, at the 95th percentile of samples — 7 MFL
worst single sample: 16.835 MFL
6/39 SYR4 2012–2017
Nitrate-Nitrite
102.5 µg/L 1%
of the EPA limit 10000 µg/L
worst single sample: 104 µg/L
6/6 SYR4 2012–2019
Barium
19.2 µg/L 1%
of the EPA limit 2000 µg/L
worst single sample: 20 µg/L
5/5 SYR4 2013–2019
Fluoride
703.7 µg/L 18%
of the EPA limit 4000 µg/L
worst single sample: 734 µg/L
4/4 SYR4 2014–2017
Chromium
6.433 µg/L 6.4%
of the EPA limit 100 µg/L
worst single sample: 6.72 µg/L
2/5 SYR4 2013–2019
Combined Radium (-226 And -228)
1 pCi/L 20%
of the EPA limit 5 pCi/L
2/2 SYR4 2013
Monobromoacetic Acid
3.91 µg/L
No EPA limit set
worst single sample: 4 µg/L
2/54 SYR4 2012–2019
Arsenic
0.7430 µg/L 7.4%
of the EPA limit 10 µg/L
1/5 SYR4 2013–2019
Atrazine
0.4000 µg/L 13%
of the EPA limit 3 µg/L
1/8 SYR4 2012–2019
Cyanide
10 µg/L 5%
of the EPA limit 200 µg/L
1/4 SYR4 2014–2017
Selenium
3.58 µg/L 7.2%
of the EPA limit 50 µg/L
1/5 SYR4 2013–2019
Thallium, Total
0.3920 µg/L 20%
of the EPA limit 2 µg/L
1/5 SYR4 2013–2019
83 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneGross Alpha, Excl. Radon And UGross Beta Particle ActivityHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
SIMMS, JERRY
Phone
915-877-2955

Frequently asked questions about Central Wcid of Angelina County

Is Central Wcid of Angelina County tap water safe to drink?

EPA monitoring detected 26 contaminants in Central Wcid of Angelina County's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Central Wcid of Angelina County's water?

EPA monitoring detected Bromodichloromethane, Dibromochloromethane, Chloroform, Dichloroacetic Acid, TTHM, and others. The full list with the level and data source for each is above.

How many people does Central Wcid of Angelina County serve?

Central Wcid of Angelina County reports serving 7,381 people in Texas, per its EPA record.

Has Central Wcid of Angelina County had any water quality violations?

The EPA has 34 violations on file for Central Wcid of Angelina County, of which 18 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.