Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2020-04-01 → 2020-06-30 |
| MCL | Health-based | Resolved | 2020-04-01 → 2020-06-30 |
| MCL | Health-based | Resolved | 2020-04-01 → 2020-06-30 |
| MR | Monitoring | Resolved | 2022-01-01 → 2022-12-31 |
| MR | Monitoring | Resolved | 2022-01-01 → 2022-12-31 |
| MR | Monitoring | Resolved | 2022-01-01 → 2022-12-31 |
| MR | Monitoring | Resolved | 2022-01-01 → 2022-12-31 |
| MR | Monitoring | Resolved | 2022-01-01 → 2022-12-31 |
| MR | Monitoring | Resolved | 2022-01-01 → 2022-12-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 797.5 µg/L 61% of the EPA limit 1300 µg/L
worst single sample: 1570 µg/L | 60/60 | SYR4 | 2013–2019 |
| Lead | 6.24 µg/L 42% of the EPA limit 15 µg/L
worst single sample: 11.1 µg/L | 60/60 | SYR4 | 2013–2019 |
| TTHM | 108.9 µg/L 136% of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 114 µg/L | 18/18 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 80.04 µg/L 133% of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 95 µg/L | 18/18 | SYR4 | 2012–2019 |
| Lead | 0.0040 mg/L 27% of the EPA limit 0.0150 mg/L | 14/14 | LCR | 2025 |
| Nitrate | 3200 µg/L 32% of the EPA limit 10000 µg/L | 12/12 | SYR4 | 2017–2019 |
| Lithium | 52.2 µg/L No EPA limit set | 4/4 | UCMR-5 | 2023 |
| Antimony, Total | 0.3900 µg/L 6.5% of the EPA limit 6 µg/L
worst single sample: 0.4000 µg/L | 2/2 | SYR4 | 2013 |
| Arsenic | 2 µg/L 20% of the EPA limit 10 µg/L | 2/2 | SYR4 | 2013 |
| Barium | 103.275 µg/L 5.2% of the EPA limit 2000 µg/L
worst single sample: 105 µg/L | 2/2 | SYR4 | 2013 |
| Chromium | 9.66 µg/L 9.7% of the EPA limit 100 µg/L
worst single sample: 9.7 µg/L | 2/2 | SYR4 | 2013 |
| Gross Alpha, Excl. Radon And U | 6.735 pCi/L 45% of the EPA limit 15 pCi/L
worst single sample: 6.8 pCi/L | 2/2 | SYR4 | 2019 |
| Selenium | 2.78 µg/L 5.6% of the EPA limit 50 µg/L
worst single sample: 2.8 µg/L | 2/2 | SYR4 | 2013 |
37 contaminants tested, none detected
Utility contact
Frequently asked questions about Sioux Rural Water
Is Sioux Rural Water tap water safe to drink?
EPA monitoring detected 13 contaminants in Sioux Rural Water's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Sioux Rural Water's water?
EPA monitoring detected Copper, Lead, TTHM, Total Haloacetic Acids (HAA5), Lead, and others. The full list with the level and data source for each is above.
How many people does Sioux Rural Water serve?
Sioux Rural Water reports serving 4,280 people in South Dakota, per its EPA record.
Has Sioux Rural Water had any water quality violations?
The EPA has 9 violations on file for Sioux Rural Water, of which 3 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.