← South Dakota

Tap water quality report

Lake Andes

EPA monitoring tested this supplier for 5 contaminants and detected 5. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

5
contaminants tested
5
detected
710
people served
19
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Charles Mix

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

19
health-based violations
46
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2020-07-25
TT Health-based Resolved 2020-07-25
TT Health-based Resolved 2019-02-01
TT Health-based Resolved 2019-02-01
TT Health-based Resolved 2010-10-23 → 2011-12-19
TT Health-based Resolved 2010-10-23 → 2011-12-19
TT Health-based Resolved 2010-04-26 → 2025-12-31
TT Health-based Resolved 2010-04-26 → 2025-12-31
TT Health-based Resolved 2010-02-01
TT Health-based Resolved 2010-02-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
151.5 µg/L 12%
of the EPA limit 1300 µg/L
worst single sample: 200 µg/L
40/40 SYR4 2012–2017
Lead
12.45 µg/L 83%
of the EPA limit 15 µg/L
worst single sample: 87.3 µg/L
40/40 SYR4 2012–2017
Lead
0.0020 mg/L 13%
of the EPA limit 0.0150 mg/L
19/19 LCR 2023
TTHM
67.76 µg/L 85%
of the EPA limit 80 µg/L
worst single sample: 68.3 µg/L
13/13 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
38.14 µg/L 64%
of the EPA limit 60 µg/L
worst single sample: 38.5 µg/L
13/13 SYR4 2013–2019

Utility contact

Contact
TIM MEDICINE HORN
Phone
6054877694
Email
[email protected]

Frequently asked questions about Lake Andes

Is Lake Andes tap water safe to drink?

EPA monitoring detected 5 contaminants in Lake Andes's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Lake Andes's water?

EPA monitoring detected Copper, Lead, Lead, TTHM, Total Haloacetic Acids (HAA5). The full list with the level and data source for each is above.

How many people does Lake Andes serve?

Lake Andes reports serving 710 people in South Dakota, per its EPA record.

Has Lake Andes had any water quality violations?

The EPA has 46 violations on file for Lake Andes, of which 19 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.