← South Carolina

Tap water quality report

Bgwc Wintercrest (sc4650017)

EPA monitoring tested this supplier for 76 contaminants and detected 10. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

76
contaminants tested
10
detected
503
people served
8
health-based violations
Water source
Ground water
Ownership
Private
Counties served
York

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

8
health-based violations
365
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 1997-06-01 → 1997-06-30
MCL Health-based Archived 1997-06-01 → 1997-06-30
MCL Health-based Archived 1997-06-01 → 1997-06-30
MCL Health-based Archived 1997-06-01 → 1997-06-30
MCL Health-based Archived 1997-06-01 → 1997-06-30
MCL Health-based Archived 1997-06-01 → 1997-06-30
TT Health-based Resolved 1994-07-01
TT Health-based Resolved 1994-07-01
MR Monitoring Resolved 2002-10-01
MR Monitoring Resolved 2002-10-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
2300 µg/L 23%
of the EPA limit 10000 µg/L
worst single sample: 2400 µg/L
48/48 SYR4 2012–2019
Copper
1360 µg/L 105%
of the EPA limit, at the 95th percentile of samples — 1300 µg/L
worst single sample: 1700 µg/L
45/45 SYR4 2012–2016
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
20/20 LCR 2023
Lead
3.6 µg/L 24%
of the EPA limit 15 µg/L
worst single sample: 4 µg/L
9/45 SYR4 2012–2016
Barium
82.6 µg/L 4.1%
of the EPA limit 2000 µg/L
worst single sample: 84 µg/L
3/6 SYR4 2014–2017
Fluoride
758 µg/L 19%
of the EPA limit 4000 µg/L
worst single sample: 760 µg/L
3/6 SYR4 2014–2017
TTHM
1.28 µg/L 1.6%
of the EPA limit 80 µg/L
worst single sample: 1.3 µg/L
3/4 SYR4 2014–2019
Chloroform
1.29 µg/L
No EPA limit set
worst single sample: 1.3 µg/L
2/4 SYR4 2014–2019
Combined Radium (-226 And -228)
3.47198 pCi/L 69%
of the EPA limit 5 pCi/L
worst single sample: 3.65 pCi/L
2/3 SYR4 2019
Dibromochloromethane
1 µg/L
No EPA limit set
1/4 SYR4 2014–2019
66 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromodichloromethaneBromoformChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDichloroacetic AcidDinosebDiquatEthylene DibromideEndrinEthylbenzeneGlyphosateGross Beta Particle ActivityHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Haloacetic Acids (HAA5)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
BLUE GRANITE WATER COMPANY
Phone
864-483-4268
Email
[email protected]

Frequently asked questions about Bgwc Wintercrest (sc4650017)

Is Bgwc Wintercrest (sc4650017) tap water safe to drink?

EPA monitoring detected 10 contaminants in Bgwc Wintercrest (sc4650017)'s water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Bgwc Wintercrest (sc4650017)'s water?

EPA monitoring detected Nitrate, Copper, Lead, Lead, Barium, and others. The full list with the level and data source for each is above.

How many people does Bgwc Wintercrest (sc4650017) serve?

Bgwc Wintercrest (sc4650017) reports serving 503 people in South Carolina, per its EPA record.

Has Bgwc Wintercrest (sc4650017) had any water quality violations?

The EPA has 365 violations on file for Bgwc Wintercrest (sc4650017), of which 8 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.