Tap water quality report

Saluda Cpw (sc4110001)

EPA monitoring tested this supplier for 44 contaminants and detected 18. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

44
contaminants tested
18
detected
3,390
people served
77
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Saluda

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

77
health-based violations
86
violations on file
3
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
MCL Health-based Resolved 2022-04-01 → 2022-06-30
MCL Health-based Resolved 2022-04-01 → 2022-06-30
MCL Health-based Resolved 2022-04-01 → 2022-06-30
MCL Health-based Resolved 2022-04-01 → 2022-06-30
MCL Health-based Resolved 2022-04-01 → 2022-06-30
MCL Health-based Resolved 2022-04-01 → 2022-06-30
MCL Health-based Resolved 2022-01-01 → 2022-03-31

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
PFOA 0.0065 µg/L 3/3 2025
PFOS 0.0099 µg/L 3/3 2025
Hfpo-Da 0.0390 µg/L 2/3 2025
PFBS 0.0042 µg/L 2/3 2025
Pfhxa 0.0062 µg/L 2/3 2025
Pfpea 0.0079 µg/L 1/3 2025

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
17.525 µg/L
No EPA limit set
worst single sample: 21.6 µg/L
46/46 SYR4 2013–2019
Chloroform
78.1 µg/L
No EPA limit set
worst single sample: 94.5 µg/L
46/46 SYR4 2013–2019
Dichloroacetic Acid
27.825 µg/L
No EPA limit set
worst single sample: 29.6 µg/L
46/46 SYR4 2013–2019
TTHM
100.275 µg/L 125%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 112.6 µg/L
46/46 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
47.2 µg/L 79%
of the EPA limit 60 µg/L
worst single sample: 53.4 µg/L
46/46 SYR4 2013–2019
Trichloroacetic Acid
21.025 µg/L
No EPA limit set
worst single sample: 26.6 µg/L
46/46 SYR4 2013–2019
Dibromochloromethane
4.865 µg/L
No EPA limit set
worst single sample: 5.2 µg/L
42/46 SYR4 2013–2019
Copper
123 µg/L 9.5%
of the EPA limit 1300 µg/L
worst single sample: 150 µg/L
38/40 SYR4 2012–2018
Lead
1.056 µg/L 7%
of the EPA limit 15 µg/L
worst single sample: 2.6 µg/L
17/40 SYR4 2012–2018
Lead
0.00031 mg/L 2.1%
of the EPA limit 0.0150 mg/L
15/15 LCR 2024
Dibromoacetic Acid
1.19 µg/L
No EPA limit set
worst single sample: 1.2 µg/L
3/46 SYR4 2013–2019
Monochloroacetic Acid
2.19 µg/L
No EPA limit set
worst single sample: 2.2 µg/L
3/46 SYR4 2013–2019
26 contaminants tested, none detected
11Cl-PF3OUdS4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaBromoformMonobromoacetic AcidNetfosaaNfdhaNmefosaaPfbaPfdaPfdoaPfeesaPfhpaPfhpsPFHXSPfmbaPfmpaPFNAPfpesPftaPftrdaPfunaLithium

Utility contact

Contact
LORRICK, JOHN
Phone
864-445-2090
Email
[email protected]

Frequently asked questions about Saluda Cpw (sc4110001)

Is Saluda Cpw (sc4110001) tap water safe to drink?

EPA monitoring detected 18 contaminants in Saluda Cpw (sc4110001)'s water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Saluda Cpw (sc4110001)'s water?

EPA monitoring detected Bromodichloromethane, Chloroform, Dichloroacetic Acid, TTHM, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.

How many people does Saluda Cpw (sc4110001) serve?

Saluda Cpw (sc4110001) reports serving 3,390 people in South Carolina, per its EPA record.

Has Saluda Cpw (sc4110001) had any water quality violations?

The EPA has 86 violations on file for Saluda Cpw (sc4110001), of which 77 are health-based (a contaminant limit or required treatment was breached) and 3 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.