← South Carolina

Tap water quality report

Easley Combined Util (sc3910002)

EPA monitoring tested this supplier for 107 contaminants and detected 14. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

107
contaminants tested
14
detected
36,098
people served
4
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Pickens

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

4
health-based violations
27
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2005-01-01 → 2005-01-31
TT Health-based Resolved 2005-01-01 → 2005-01-31
TT Health-based Resolved 2005-01-01 → 2005-01-31
TT Health-based Resolved 2005-01-01 → 2005-01-31
Other Monitoring Resolved 2007-07-01
Other Monitoring Resolved 2007-07-01
Other Monitoring Resolved 2007-07-01
MR Monitoring Archived 1999-04-01 → 1999-04-30
MR Monitoring Resolved 1998-08-01 → 1998-08-31
MR Monitoring Resolved 1998-08-01 → 1998-08-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
9.0235 µg/L
No EPA limit set
worst single sample: 11.05 µg/L
128/128 SYR4 2012–2019
Chloroform
41.4 µg/L
No EPA limit set
worst single sample: 59 µg/L
128/128 SYR4 2012–2019
TTHM
50.195 µg/L 63%
of the EPA limit 80 µg/L
worst single sample: 70.2 µg/L
128/128 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
49.7165 µg/L 83%
of the EPA limit 60 µg/L
worst single sample: 65.2 µg/L
128/128 SYR4 2012–2019
Trichloroacetic Acid
20.6195 µg/L
No EPA limit set
worst single sample: 27.01 µg/L
128/128 SYR4 2012–2019
Dichloroacetic Acid
27.203 µg/L
No EPA limit set
worst single sample: 44.4 µg/L
127/128 SYR4 2012–2019
Copper
360 µg/L 28%
of the EPA limit 1300 µg/L
worst single sample: 444 µg/L
90/90 SYR4 2013–2019
Dibromochloromethane
1.9045 µg/L
No EPA limit set
worst single sample: 2.1 µg/L
78/128 SYR4 2012–2019
Lead
10 µg/L 67%
of the EPA limit 15 µg/L
worst single sample: 260 µg/L
28/90 SYR4 2013–2019
Nitrate
570 µg/L 5.7%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
15/15 LCR 2025
Monobromoacetic Acid
3.727 µg/L
No EPA limit set
worst single sample: 3.79 µg/L
15/128 SYR4 2012–2019
Fluoride
627.5 µg/L 16%
of the EPA limit 4000 µg/L
worst single sample: 680 µg/L
8/8 SYR4 2012–2019
Monochloroacetic Acid
2.92 µg/L
No EPA limit set
worst single sample: 3.1 µg/L
5/128 SYR4 2012–2019
93 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAtrazineBhc-GammaBariumBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined Radium (-226 And -228)Combined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDinosebDiquatEthylene DibromideEndrinEthylbenzeneGlyphosateGross Alpha, Excl. Radon And UGross Beta Particle ActivityHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
DAVIS, TATE
Phone
864-859-4013
Email
[email protected]; [email protected]

Frequently asked questions about Easley Combined Util (sc3910002)

Is Easley Combined Util (sc3910002) tap water safe to drink?

EPA monitoring detected 14 contaminants in Easley Combined Util (sc3910002)'s water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Easley Combined Util (sc3910002)'s water?

EPA monitoring detected Bromodichloromethane, Chloroform, TTHM, Total Haloacetic Acids (HAA5), Trichloroacetic Acid, and others. The full list with the level and data source for each is above.

How many people does Easley Combined Util (sc3910002) serve?

Easley Combined Util (sc3910002) reports serving 36,098 people in South Carolina, per its EPA record.

Has Easley Combined Util (sc3910002) had any water quality violations?

The EPA has 27 violations on file for Easley Combined Util (sc3910002), of which 4 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.