Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MR | Monitoring | Archived | 2001-04-01 → 2001-04-30 |
| MR | Monitoring | Resolved | 1993-07-01 → 1993-09-30 |
| MR | Monitoring | Resolved | 1993-07-01 → 1993-09-30 |
| MR | Monitoring | Resolved | 1993-04-01 → 1993-06-30 |
| MR | Monitoring | Resolved | 1993-01-01 → 1993-01-31 |
| MR | Monitoring | Resolved | 1993-01-01 → 1993-01-31 |
| MR | Monitoring | Resolved | 1993-01-01 → 1993-01-31 |
| MR | Monitoring | Resolved | 1993-01-01 → 1993-01-31 |
| MR | Monitoring | Resolved | 1993-01-01 → 1993-01-31 |
| MR | Monitoring | Resolved | 1993-01-01 → 1993-01-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Bromodichloromethane | 8.1965 µg/L No EPA limit set
worst single sample: 9.54 µg/L | 128/128 | SYR4 | 2012–2019 |
| Chloroform | 52.45 µg/L No EPA limit set
worst single sample: 74.5 µg/L | 128/128 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 16.515 µg/L No EPA limit set
worst single sample: 20.6 µg/L | 128/128 | SYR4 | 2012–2019 |
| TTHM | 59.395 µg/L 74% of the EPA limit 80 µg/L
worst single sample: 85.1 µg/L | 128/128 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 28.265 µg/L 47% of the EPA limit 60 µg/L
worst single sample: 37.7 µg/L | 128/128 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 13.665 µg/L No EPA limit set
worst single sample: 21.7 µg/L | 128/128 | SYR4 | 2012–2019 |
| Copper | 71.95 µg/L 5.5% of the EPA limit 1300 µg/L
worst single sample: 110 µg/L | 82/90 | SYR4 | 2013–2019 |
| Dibromochloromethane | 2.1 µg/L No EPA limit set
worst single sample: 2.26 µg/L | 79/128 | SYR4 | 2012–2019 |
| Lead | 0.0030 mg/L 20% of the EPA limit 0.0150 mg/L | 20/20 | LCR | 2025 |
| Nitrate | 67 µg/L 0.7% of the EPA limit 10000 µg/L | 16/16 | SYR4 | 2012–2019 |
| Monobromoacetic Acid | 1.979 µg/L No EPA limit set
worst single sample: 2.06 µg/L | 10/128 | SYR4 | 2012–2019 |
| Fluoride | 891 µg/L 22% of the EPA limit 4000 µg/L
worst single sample: 900 µg/L | 7/8 | SYR4 | 2012–2019 |
| Lead | 18.5 µg/L 123% of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 23 µg/L | 6/90 | SYR4 | 2013–2019 |
| Gross Alpha, Excl. Radon And U | 1.4 pCi/L 9.3% of the EPA limit 15 pCi/L | 1/1 | SYR4 | 2015 |
| Nitrate-Nitrite | 28 µg/L 0.3% of the EPA limit 10000 µg/L | 1/1 | SYR4 | 2012 |
92 contaminants tested, none detected
Utility contact
Frequently asked questions about Seneca City of (sc3710002)
Is Seneca City of (sc3710002) tap water safe to drink?
EPA monitoring detected 15 contaminants in Seneca City of (sc3710002)'s water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Seneca City of (sc3710002)'s water?
EPA monitoring detected Bromodichloromethane, Chloroform, Dichloroacetic Acid, TTHM, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.
How many people does Seneca City of (sc3710002) serve?
Seneca City of (sc3710002) reports serving 39,772 people in South Carolina, per its EPA record.
Has Seneca City of (sc3710002) had any water quality violations?
The EPA has 17 violations on file for Seneca City of (sc3710002), of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.