Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2010-04-01 → 2010-06-30 |
| MCL | Health-based | Resolved | 2010-04-01 → 2010-06-30 |
| MCL | Health-based | Resolved | 2010-04-01 → 2010-06-30 |
| MCL | Health-based | Resolved | 2010-04-01 → 2010-06-30 |
| MCL | Health-based | Resolved | 2010-01-01 → 2010-03-31 |
| MCL | Health-based | Resolved | 2010-01-01 → 2010-03-31 |
| MCL | Health-based | Resolved | 2010-01-01 → 2010-03-31 |
| MCL | Health-based | Resolved | 2010-01-01 → 2010-03-31 |
| MCL | Health-based | Resolved | 2010-01-01 → 2010-03-31 |
| MCL | Health-based | Resolved | 2009-10-01 → 2009-12-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 247.5 µg/L 19% of the EPA limit 1300 µg/L
worst single sample: 370 µg/L | 56/60 | SYR4 | 2014–2017 |
| Nitrate | 1200 µg/L 12% of the EPA limit 10000 µg/L | 46/48 | SYR4 | 2012–2019 |
| Combined Radium (-226 And -228) | 2.804 pCi/L 56% of the EPA limit 5 pCi/L
worst single sample: 5.4 pCi/L | 33/45 | SYR4 | 2012–2019 |
| Lead | 0.0016 mg/L 11% of the EPA limit 0.0150 mg/L | 20/20 | LCR | 2023 |
| Lead | 7.33 µg/L 49% of the EPA limit 15 µg/L
worst single sample: 8.1 µg/L | 12/60 | SYR4 | 2014–2017 |
| TTHM | 2.6585 µg/L 3.3% of the EPA limit 80 µg/L
worst single sample: 2.78 µg/L | 10/98 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 29.432 µg/L 49% of the EPA limit 60 µg/L
worst single sample: 29.82 µg/L | 9/98 | SYR4 | 2012–2019 |
| Chloroform | 2.384 µg/L No EPA limit set
worst single sample: 2.51 µg/L | 8/98 | SYR4 | 2012–2019 |
| Fluoride | 1031 µg/L 26% of the EPA limit 4000 µg/L
worst single sample: 1100 µg/L | 7/8 | SYR4 | 2014–2018 |
| Gross Alpha, Excl. Radon And U | 4.625 pCi/L 31% of the EPA limit 15 pCi/L
worst single sample: 5 pCi/L | 6/37 | SYR4 | 2012–2018 |
| 1,2-DIBROMO-3-CHLOROPROPANE | 0.0342 µg/L 17% of the EPA limit 0.2000 µg/L
worst single sample: 0.0360 µg/L | 5/19 | SYR4 | 2014–2019 |
| Dichloroacetic Acid | 29.723 µg/L No EPA limit set
worst single sample: 29.82 µg/L | 3/98 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 1.401 µg/L No EPA limit set
worst single sample: 1.43 µg/L | 3/98 | SYR4 | 2012–2019 |
| Bromodichloromethane | 1.504 µg/L No EPA limit set
worst single sample: 1.53 µg/L | 2/98 | SYR4 | 2012–2019 |
| Monobromoacetic Acid | 1.36178 µg/L No EPA limit set
worst single sample: 1.3655 µg/L | 2/98 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 1.37 µg/L No EPA limit set | 1/98 | SYR4 | 2012–2019 |
| Dibromochloromethane | 1.25 µg/L No EPA limit set | 1/98 | SYR4 | 2012–2019 |
| Ethylene Dibromide | 0.0220 µg/L 44% of the EPA limit 0.0500 µg/L | 1/19 | SYR4 | 2014–2019 |
| Nitrate-Nitrite | 200 µg/L 2% of the EPA limit 10000 µg/L | 1/1 | SYR4 | 2019 |
90 contaminants tested, none detected
Utility contact
Frequently asked questions about Darlington County W&Sa (sc1620001)
Is Darlington County W&Sa (sc1620001) tap water safe to drink?
EPA monitoring detected 19 contaminants in Darlington County W&Sa (sc1620001)'s water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Darlington County W&Sa (sc1620001)'s water?
EPA monitoring detected Copper, Nitrate, Combined Radium (-226 And -228), Lead, Lead, and others. The full list with the level and data source for each is above.
How many people does Darlington County W&Sa (sc1620001) serve?
Darlington County W&Sa (sc1620001) reports serving 52,288 people in South Carolina, per its EPA record.
Has Darlington County W&Sa (sc1620001) had any water quality violations?
The EPA has 16 violations on file for Darlington County W&Sa (sc1620001), of which 16 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.