← South Carolina

Tap water quality report

Alligator Rural Water (sc1320004)

EPA monitoring tested this supplier for 109 contaminants and detected 12. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

109
contaminants tested
12
detected
4,743
people served
11
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Chesterfield

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

11
health-based violations
29
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2009-04-01 → 2009-06-30
MCL Health-based Resolved 2009-04-01 → 2009-06-30
MCL Health-based Resolved 2009-04-01 → 2009-06-30
MCL Health-based Resolved 2009-04-01 → 2009-06-30
MCL Health-based Resolved 2007-01-01 → 2007-12-31
MCL Health-based Resolved 2007-01-01 → 2007-12-31
MCL Health-based Resolved 2007-01-01 → 2007-12-31
MCL Health-based Resolved 2006-01-01 → 2006-03-31
MCL Health-based Resolved 2006-01-01 → 2006-03-31
TT Health-based Resolved 1996-01-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
83.4 µg/L 6.4%
of the EPA limit 1300 µg/L
worst single sample: 400 µg/L
79/156 SYR4 2012–2019
Nitrate
2905 µg/L 29%
of the EPA limit 10000 µg/L
worst single sample: 3400 µg/L
30/30 SYR4 2012–2019
Lead
36.8 µg/L 245%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 53 µg/L
24/156 SYR4 2012–2019
Lead
0.00015 mg/L 1%
of the EPA limit 0.0150 mg/L
20/20 LCR 2025
1,2-DIBROMO-3-CHLOROPROPANE
0.0748 µg/L 37%
of the EPA limit 0.2000 µg/L
worst single sample: 0.0770 µg/L
12/35 SYR4 2012–2019
Combined Radium (-226 And -228)
5 pCi/L 100%
of the EPA limit 5 pCi/L
9/13 SYR4 2012–2018
Gross Alpha, Excl. Radon And U
6.2 pCi/L 41%
of the EPA limit 15 pCi/L
worst single sample: 6.7 pCi/L
5/12 SYR4 2012–2018
Dibromochloromethane
1.49692 µg/L
No EPA limit set
worst single sample: 1.53 µg/L
3/13 SYR4 2013–2019
TTHM
2.48896 µg/L 3.1%
of the EPA limit 80 µg/L
worst single sample: 2.5041 µg/L
3/13 SYR4 2013–2019
Bromodichloromethane
1.3013 µg/L
No EPA limit set
worst single sample: 1.3049 µg/L
2/13 SYR4 2013–2019
Combined Uranium
9.695 µg/L 32%
of the EPA limit 30 µg/L
worst single sample: 9.9 µg/L
2/4 SYR4 2012–2013
Nitrate-Nitrite
1400 µg/L 14%
of the EPA limit 10000 µg/L
1/1 SYR4 2012
97 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAtrazineBhc-GammaBariumBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneChloroformChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDichloroacetic AcidDinosebDiquatEthylene DibromideEndrinEthylbenzeneFluorideGlyphosateGross Beta Particle ActivityHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Haloacetic Acids (HAA5)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
WATKINS, SYDNEY
Phone
843-335-6464
Email
[email protected]

Frequently asked questions about Alligator Rural Water (sc1320004)

Is Alligator Rural Water (sc1320004) tap water safe to drink?

EPA monitoring detected 12 contaminants in Alligator Rural Water (sc1320004)'s water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Alligator Rural Water (sc1320004)'s water?

EPA monitoring detected Copper, Nitrate, Lead, Lead, 1,2-DIBROMO-3-CHLOROPROPANE, and others. The full list with the level and data source for each is above.

How many people does Alligator Rural Water (sc1320004) serve?

Alligator Rural Water (sc1320004) reports serving 4,743 people in South Carolina, per its EPA record.

Has Alligator Rural Water (sc1320004) had any water quality violations?

The EPA has 29 violations on file for Alligator Rural Water (sc1320004), of which 11 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.