Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 1994-07-01 → 1994-09-30 |
| MCL | Health-based | Resolved | 1994-07-01 → 1994-09-30 |
| MCL | Health-based | Resolved | 1994-07-01 → 1994-09-30 |
| MCL | Health-based | Resolved | 1994-04-01 → 1994-06-30 |
| MCL | Health-based | Resolved | 1994-04-01 → 1994-06-30 |
| MCL | Health-based | Resolved | 1994-04-01 → 1994-06-30 |
| MCL | Health-based | Resolved | 1994-01-01 → 1994-03-31 |
| MCL | Health-based | Resolved | 1994-01-01 → 1994-03-31 |
| MCL | Health-based | Resolved | 1994-01-01 → 1994-03-31 |
| MCL | Health-based | Resolved | 1993-10-01 → 1993-12-31 |
PFAS detected
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Bromodichloromethane | 18.2855 µg/L No EPA limit set
worst single sample: 25.1 µg/L | 128/128 | SYR4 | 2012–2019 |
| Chloroform | 31.83 µg/L No EPA limit set
worst single sample: 37.1 µg/L | 128/128 | SYR4 | 2012–2019 |
| Dibromochloromethane | 15.995 µg/L No EPA limit set
worst single sample: 18.4 µg/L | 128/128 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 18.995 µg/L No EPA limit set
worst single sample: 26.3 µg/L | 128/128 | SYR4 | 2012–2019 |
| TTHM | 55.837 µg/L 70% of the EPA limit 80 µg/L
worst single sample: 71.6 µg/L | 128/128 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 33.3565 µg/L 56% of the EPA limit 60 µg/L
worst single sample: 45 µg/L | 128/128 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 10.795 µg/L No EPA limit set
worst single sample: 14 µg/L | 128/128 | SYR4 | 2012–2019 |
| Copper | 138.25 µg/L 11% of the EPA limit 1300 µg/L
worst single sample: 542 µg/L | 88/92 | SYR4 | 2013–2019 |
| Dibromoacetic Acid | 5.63 µg/L No EPA limit set
worst single sample: 6.4 µg/L | 83/128 | SYR4 | 2012–2019 |
| Bromoform | 4.54 µg/L No EPA limit set
worst single sample: 5.5 µg/L | 40/128 | SYR4 | 2012–2019 |
| Lead | 35.5 µg/L 237% of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 700 µg/L | 26/92 | SYR4 | 2013–2019 |
| Monobromoacetic Acid | 8.4765 µg/L No EPA limit set
worst single sample: 8.68 µg/L | 24/128 | SYR4 | 2012–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 16/16 | LCR | 2025 |
| Nitrate | 1900 µg/L 19% of the EPA limit 10000 µg/L | 16/16 | SYR4 | 2012–2019 |
| Monochloroacetic Acid | 3.34 µg/L No EPA limit set
worst single sample: 3.5 µg/L | 9/128 | SYR4 | 2012–2019 |
| Fluoride | 603 µg/L 15% of the EPA limit 4000 µg/L
worst single sample: 630 µg/L | 7/8 | SYR4 | 2012–2019 |
| 2,4-D | 0.7100 µg/L 1% of the EPA limit 70 µg/L | 1/20 | SYR4 | 2012–2019 |
84 contaminants tested, none detected
Utility contact
Frequently asked questions about Chester Metropolitan District (1220002)
Is Chester Metropolitan District (1220002) tap water safe to drink?
EPA monitoring detected 21 contaminants in Chester Metropolitan District (1220002)'s water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Chester Metropolitan District (1220002)'s water?
EPA monitoring detected Bromodichloromethane, Chloroform, Dibromochloromethane, Dichloroacetic Acid, TTHM, and others. The full list with the level and data source for each is above.
How many people does Chester Metropolitan District (1220002) serve?
Chester Metropolitan District (1220002) reports serving 15,668 people in South Carolina, per its EPA record.
Has Chester Metropolitan District (1220002) had any water quality violations?
The EPA has 37 violations on file for Chester Metropolitan District (1220002), of which 15 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.