Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2014-01-01 → 2014-03-31 |
| MCL | Health-based | Resolved | 2014-01-01 → 2014-03-31 |
| MCL | Health-based | Resolved | 2014-01-01 → 2014-03-31 |
| MCL | Health-based | Resolved | 2014-01-01 → 2014-03-31 |
| MCL | Health-based | Resolved | 2014-01-01 → 2014-03-31 |
| MCL | Health-based | Resolved | 2014-01-01 → 2014-03-31 |
| MCL | Health-based | Resolved | 2014-01-01 → 2014-03-31 |
| MCL | Health-based | Resolved | 2014-01-01 → 2014-03-31 |
| MCL | Health-based | Archived | 1992-07-01 → 1992-07-31 |
| MR | Monitoring | Resolved | 2001-10-01 |
PFAS detected
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Bromodichloromethane | 14.61 µg/L No EPA limit set
worst single sample: 16.5 µg/L | 63/63 | SYR4 | 2012–2019 |
| Chloroform | 80.02 µg/L No EPA limit set
worst single sample: 95 µg/L | 63/63 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 25.21 µg/L No EPA limit set
worst single sample: 32.12 µg/L | 63/63 | SYR4 | 2012–2019 |
| TTHM | 94.01 µg/L 118% of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 111.1 µg/L | 63/63 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 51.468 µg/L 86% of the EPA limit 60 µg/L
worst single sample: 61.03 µg/L | 63/63 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 27.41 µg/L No EPA limit set
worst single sample: 28.4 µg/L | 63/63 | SYR4 | 2012–2019 |
| Dibromochloromethane | 3.64 µg/L No EPA limit set
worst single sample: 7.2 µg/L | 59/63 | SYR4 | 2012–2019 |
| Copper | 112.5 µg/L 8.7% of the EPA limit 1300 µg/L
worst single sample: 140 µg/L | 31/40 | SYR4 | 2014–2017 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 15/15 | LCR | 2023 |
| Monobromoacetic Acid | 5.4 µg/L No EPA limit set
worst single sample: 5.79 µg/L | 7/63 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 1.185 µg/L No EPA limit set
worst single sample: 1.2 µg/L | 4/63 | SYR4 | 2012–2019 |
| Lead | 18.6 µg/L 124% of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 21 µg/L | 4/40 | SYR4 | 2014–2017 |
| Monochloroacetic Acid | 2.57 µg/L No EPA limit set
worst single sample: 2.6 µg/L | 2/63 | SYR4 | 2012–2019 |
24 contaminants tested, none detected
Utility contact
Frequently asked questions about Goucher Wd (1120004)
Is Goucher Wd (1120004) tap water safe to drink?
EPA monitoring detected 20 contaminants in Goucher Wd (1120004)'s water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Goucher Wd (1120004)'s water?
EPA monitoring detected Bromodichloromethane, Chloroform, Dichloroacetic Acid, TTHM, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.
How many people does Goucher Wd (1120004) serve?
Goucher Wd (1120004) reports serving 5,323 people in South Carolina, per its EPA record.
Has Goucher Wd (1120004) had any water quality violations?
The EPA has 12 violations on file for Goucher Wd (1120004), of which 9 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.