Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MR | Monitoring | Resolved | 2010-07-02 |
PFAS detected
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Bromodichloromethane | 14.53 µg/L No EPA limit set
worst single sample: 16.2 µg/L | 116/116 | SYR4 | 2012–2019 |
| Chloroform | 22.1975 µg/L No EPA limit set
worst single sample: 25.14 µg/L | 116/116 | SYR4 | 2012–2019 |
| TTHM | 41.9375 µg/L 52% of the EPA limit 80 µg/L
worst single sample: 55.2 µg/L | 116/116 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 36.048 µg/L 60% of the EPA limit 60 µg/L
worst single sample: 55.36 µg/L | 113/116 | SYR4 | 2012–2019 |
| Monobromoacetic Acid | 7.625 µg/L No EPA limit set
worst single sample: 12.06 µg/L | 111/116 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 11.466 µg/L No EPA limit set
worst single sample: 15.27 µg/L | 109/116 | SYR4 | 2012–2019 |
| Dibromochloromethane | 14.5735 µg/L No EPA limit set
worst single sample: 22.58 µg/L | 108/116 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 18.0375 µg/L No EPA limit set
worst single sample: 39.36 µg/L | 106/116 | SYR4 | 2012–2019 |
| Copper | 120 µg/L 9.2% of the EPA limit 1300 µg/L
worst single sample: 217.8 µg/L | 52/60 | SYR4 | 2013–2019 |
| Lead | 2.01 µg/L 13% of the EPA limit 15 µg/L
worst single sample: 3.3 µg/L | 45/60 | SYR4 | 2013–2019 |
| Dibromoacetic Acid | 6.1755 µg/L No EPA limit set
worst single sample: 7.08 µg/L | 44/116 | SYR4 | 2012–2019 |
| Lead | 0.00070 mg/L 4.7% of the EPA limit 0.0150 mg/L | 12/12 | LCR | 2025 |
| Bromoform | 12.3805 µg/L No EPA limit set
worst single sample: 12.52 µg/L | 10/116 | SYR4 | 2012–2019 |
| Monochloroacetic Acid | 5.2245 µg/L No EPA limit set
worst single sample: 5.37 µg/L | 2/116 | SYR4 | 2012–2019 |
23 contaminants tested, none detected
Utility contact
Frequently asked questions about Bcwsa East Cooper (sc0820009)
Is Bcwsa East Cooper (sc0820009) tap water safe to drink?
EPA monitoring detected 21 contaminants in Bcwsa East Cooper (sc0820009)'s water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Bcwsa East Cooper (sc0820009)'s water?
EPA monitoring detected Bromodichloromethane, Chloroform, TTHM, Total Haloacetic Acids (HAA5), Monobromoacetic Acid, and others. The full list with the level and data source for each is above.
How many people does Bcwsa East Cooper (sc0820009) serve?
Bcwsa East Cooper (sc0820009) reports serving 12,933 people in South Carolina, per its EPA record.
Has Bcwsa East Cooper (sc0820009) had any water quality violations?
The EPA has 1 violation on file for Bcwsa East Cooper (sc0820009), of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.