Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| TT | Health-based | Resolved | 2000-01-01 |
| TT | Health-based | Resolved | 2000-01-01 |
| MCL | Health-based | Archived | 1991-03-01 → 1991-03-31 |
| MCL | Health-based | Archived | 1991-03-01 → 1991-03-31 |
| MR | Monitoring | Resolved | 2016-09-01 |
| MR | Monitoring | Resolved | 2016-09-01 |
| MR | Monitoring | Resolved | 2016-09-01 |
| MR | Monitoring | Resolved | 2016-09-01 |
| MR | Monitoring | Archived | 1992-07-01 → 1992-07-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 125.8 µg/L 9.7% of the EPA limit 1300 µg/L
worst single sample: 180 µg/L | 39/50 | SYR4 | 2012–2019 |
| Bromodichloromethane | 10.575 µg/L No EPA limit set
worst single sample: 11.4 µg/L | 26/26 | SYR4 | 2013–2019 |
| Chloroform | 54.15 µg/L No EPA limit set
worst single sample: 60.2 µg/L | 26/26 | SYR4 | 2013–2019 |
| Dibromochloromethane | 3.075 µg/L No EPA limit set
worst single sample: 3.4 µg/L | 26/26 | SYR4 | 2013–2019 |
| Dichloroacetic Acid | 16.25 µg/L No EPA limit set
worst single sample: 17.7 µg/L | 26/26 | SYR4 | 2013–2019 |
| TTHM | 66.2 µg/L 83% of the EPA limit 80 µg/L
worst single sample: 72.9 µg/L | 26/26 | SYR4 | 2013–2019 |
| Total Haloacetic Acids (HAA5) | 28.675 µg/L 48% of the EPA limit 60 µg/L
worst single sample: 30.8 µg/L | 26/26 | SYR4 | 2013–2019 |
| Trichloroacetic Acid | 12.875 µg/L No EPA limit set
worst single sample: 24.7 µg/L | 26/26 | SYR4 | 2013–2019 |
| Nitrate | 1200 µg/L 12% of the EPA limit 10000 µg/L | 14/16 | SYR4 | 2012–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 13/13 | LCR | 2025 |
| Dibromoacetic Acid | 1.275 µg/L No EPA limit set
worst single sample: 1.3 µg/L | 6/26 | SYR4 | 2013–2019 |
| Lead | 1.8405 µg/L 12% of the EPA limit 15 µg/L
worst single sample: 1.9 µg/L | 2/50 | SYR4 | 2012–2019 |
| Combined Radium (-226 And -228) | 2.3 pCi/L 46% of the EPA limit 5 pCi/L | 1/1 | SYR4 | 2014 |
| Fluoride | 110 µg/L 2.8% of the EPA limit 4000 µg/L | 1/2 | SYR4 | 2014–2017 |
63 contaminants tested, none detected
Utility contact
Frequently asked questions about Bgwc Nevitt Forest (sc0450007)
Is Bgwc Nevitt Forest (sc0450007) tap water safe to drink?
EPA monitoring detected 14 contaminants in Bgwc Nevitt Forest (sc0450007)'s water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Bgwc Nevitt Forest (sc0450007)'s water?
EPA monitoring detected Copper, Bromodichloromethane, Chloroform, Dibromochloromethane, Dichloroacetic Acid, and others. The full list with the level and data source for each is above.
How many people does Bgwc Nevitt Forest (sc0450007) serve?
Bgwc Nevitt Forest (sc0450007) reports serving 966 people in South Carolina, per its EPA record.
Has Bgwc Nevitt Forest (sc0450007) had any water quality violations?
The EPA has 9 violations on file for Bgwc Nevitt Forest (sc0450007), of which 4 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.