Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2001-10-01 → 2001-10-31 |
| MCL | Health-based | Resolved | 2001-10-01 → 2001-10-31 |
| MCL | Health-based | Resolved | 2001-10-01 → 2001-10-31 |
| MCL | Health-based | Archived | 1995-08-01 → 1995-08-31 |
| MR | Monitoring | Unaddressed | 2025-10-01 |
| MR | Monitoring | Archived | 1992-07-01 → 1992-07-31 |
| MR | Monitoring | Archived | 1992-06-01 → 1992-06-30 |
| MR | Monitoring | Archived | 1992-05-01 → 1992-05-31 |
| MR | Monitoring | Archived | 1992-04-01 → 1992-04-30 |
| MR | Monitoring | Archived | 1992-03-01 → 1992-03-31 |
PFAS detected
| Contaminant | Max | Detection rate | Period |
|---|---|---|---|
| PFBS | 0.0040 µg/L | 4/4 | 2025 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 290.1 µg/L 22% of the EPA limit 1300 µg/L
worst single sample: 420 µg/L | 119/120 | SYR4 | 2014–2019 |
| Bromodichloromethane | 8.9 µg/L No EPA limit set
worst single sample: 10.6 µg/L | 100/100 | SYR4 | 2013–2019 |
| Chloroform | 49.29 µg/L No EPA limit set
worst single sample: 66.6 µg/L | 100/100 | SYR4 | 2013–2019 |
| Dichloroacetic Acid | 16.07 µg/L No EPA limit set
worst single sample: 20.5 µg/L | 100/100 | SYR4 | 2013–2019 |
| TTHM | 60.735 µg/L 76% of the EPA limit 80 µg/L
worst single sample: 76 µg/L | 100/100 | SYR4 | 2013–2019 |
| Total Haloacetic Acids (HAA5) | 28.41 µg/L 47% of the EPA limit 60 µg/L
worst single sample: 31.1 µg/L | 100/100 | SYR4 | 2013–2019 |
| Trichloroacetic Acid | 12.7 µg/L No EPA limit set
worst single sample: 16.3 µg/L | 100/100 | SYR4 | 2013–2019 |
| Dibromochloromethane | 3.21 µg/L No EPA limit set
worst single sample: 3.6 µg/L | 99/100 | SYR4 | 2013–2019 |
| Lead | 17 µg/L 113% of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 28 µg/L | 33/120 | SYR4 | 2014–2019 |
| Dibromoacetic Acid | 1.3 µg/L No EPA limit set | 20/100 | SYR4 | 2013–2019 |
| Lead | 0.0110 mg/L 73% of the EPA limit 0.0150 mg/L | 17/17 | LCR | 2025 |
| Monochloroacetic Acid | 2 µg/L No EPA limit set | 1/100 | SYR4 | 2013–2019 |
31 contaminants tested, none detected
Utility contact
Frequently asked questions about Hammond W/D (sc0420007)
Is Hammond W/D (sc0420007) tap water safe to drink?
EPA monitoring detected 13 contaminants in Hammond W/D (sc0420007)'s water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Hammond W/D (sc0420007)'s water?
EPA monitoring detected Copper, Bromodichloromethane, Chloroform, Dichloroacetic Acid, TTHM, and others. The full list with the level and data source for each is above.
How many people does Hammond W/D (sc0420007) serve?
Hammond W/D (sc0420007) reports serving 21,193 people in South Carolina, per its EPA record.
Has Hammond W/D (sc0420007) had any water quality violations?
The EPA has 13 violations on file for Hammond W/D (sc0420007), of which 4 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.