← South Carolina

Tap water quality report

Talatha W/D (sc0220005)

EPA monitoring tested this supplier for 78 contaminants and detected 15. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

78
contaminants tested
15
detected
1,237
people served
6
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Aiken

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

6
health-based violations
11
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
MCL Health-based Resolved 1994-08-01 → 1994-08-31
MCL Health-based Resolved 1994-08-01 → 1994-08-31
RPT Monitoring Resolved 2024-10-17
RPT Monitoring Resolved 2024-10-17
RPT Monitoring Resolved 2024-10-17
RPT Monitoring Resolved 2024-10-17

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
2400 µg/L 24%
of the EPA limit 10000 µg/L
worst single sample: 2600 µg/L
50/50 SYR4 2012–2019
Copper
59.75 µg/L 4.6%
of the EPA limit 1300 µg/L
worst single sample: 86 µg/L
26/30 SYR4 2012–2018
Lead
0.00030 mg/L 2%
of the EPA limit 0.0150 mg/L
18/18 LCR 2024
Combined Radium (-226 And -228)
3.848 pCi/L 77%
of the EPA limit 5 pCi/L
worst single sample: 3.96 pCi/L
15/17 SYR4 2012–2018
Lead
5.4 µg/L 36%
of the EPA limit 15 µg/L
worst single sample: 6 µg/L
13/30 SYR4 2012–2018
Gross Alpha, Excl. Radon And U
3.533 pCi/L 24%
of the EPA limit 15 pCi/L
worst single sample: 3.56 pCi/L
10/17 SYR4 2012–2018
Bromodichloromethane
1.92 µg/L
No EPA limit set
worst single sample: 2 µg/L
5/6 SYR4 2014–2019
Dibromochloromethane
1.38 µg/L
No EPA limit set
worst single sample: 1.4 µg/L
5/6 SYR4 2014–2019
TTHM
5.38 µg/L 6.7%
of the EPA limit 80 µg/L
worst single sample: 5.6 µg/L
5/6 SYR4 2014–2019
Chloroform
2.325 µg/L
No EPA limit set
worst single sample: 2.4 µg/L
4/6 SYR4 2014–2019
Dichloroacetic Acid
1.2 µg/L
No EPA limit set
3/6 SYR4 2014–2019
Nitrate-Nitrite
2330 µg/L 23%
of the EPA limit 10000 µg/L
worst single sample: 2400 µg/L
3/3 SYR4 2014
Total Haloacetic Acids (HAA5)
1.2 µg/L 2%
of the EPA limit 60 µg/L
3/6 SYR4 2014–2019
Ethylbenzene
2.654 µg/L 0.4%
of the EPA limit 700 µg/L
worst single sample: 2.74 µg/L
2/8 SYR4 2016–2017
Xylenes, Total
17.524 µg/L 0.2%
of the EPA limit 10000 µg/L
worst single sample: 18.17 µg/L
2/8 SYR4 2016–2017
63 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBariumBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDinosebDiquatEthylene DibromideEndrinFluorideGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroacetic AcidTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
HOLMES, JERMAINE
Phone
803-652-1381
Email
[email protected]

Frequently asked questions about Talatha W/D (sc0220005)

Is Talatha W/D (sc0220005) tap water safe to drink?

EPA monitoring detected 15 contaminants in Talatha W/D (sc0220005)'s water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Talatha W/D (sc0220005)'s water?

EPA monitoring detected Nitrate, Copper, Lead, Combined Radium (-226 And -228), Lead, and others. The full list with the level and data source for each is above.

How many people does Talatha W/D (sc0220005) serve?

Talatha W/D (sc0220005) reports serving 1,237 people in South Carolina, per its EPA record.

Has Talatha W/D (sc0220005) had any water quality violations?

The EPA has 11 violations on file for Talatha W/D (sc0220005), of which 6 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.