← Rhode Island

Tap water quality report

Exeter Job Corps Center

EPA monitoring tested this supplier for 14 contaminants and detected 11. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

14
contaminants tested
11
detected
300
people served
3
health-based violations
Water source
GWP
Ownership
State government
Counties served
Washington

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

3
health-based violations
58
violations on file
7
still open
ViolationTypeStatusPeriod
TT Health-based Unaddressed 2025-08-28
TT Health-based Unaddressed 2025-08-28
TT Health-based Unaddressed 2025-08-28
MR Monitoring Unaddressed 2026-01-01
MR Monitoring Unaddressed 2026-01-01
MR Monitoring Unaddressed 2026-01-01
MR Monitoring Unaddressed 2025-12-30
MR Monitoring Resolved 2024-10-01 → 2024-10-31
MR Monitoring Resolved 2024-10-01 → 2024-10-31
MR Monitoring Resolved 2024-10-01 → 2024-10-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
545.5 µg/L 42%
of the EPA limit 1300 µg/L
worst single sample: 1020 µg/L
60/60 SYR4 2018–2019
Lead
0.0188 mg/L 125%
above the EPA limit of 0.0150 mg/L
28/28 LCR 2025
Lead
2.865 µg/L 19%
of the EPA limit 15 µg/L
worst single sample: 3.8 µg/L
12/60 SYR4 2018–2019
Dibromochloromethane
5.4 µg/L
No EPA limit set
worst single sample: 5.5 µg/L
11/12 SYR4 2018–2019
TTHM
15.8 µg/L 20%
of the EPA limit 80 µg/L
worst single sample: 15.9 µg/L
11/12 SYR4 2018–2019
Bromodichloromethane
5.16 µg/L
No EPA limit set
worst single sample: 5.2 µg/L
9/12 SYR4 2018–2019
Bromoform
3.42 µg/L
No EPA limit set
worst single sample: 3.7 µg/L
9/12 SYR4 2018–2019
Dibromoacetic Acid
1.795 µg/L
No EPA limit set
worst single sample: 1.9 µg/L
8/12 SYR4 2018–2019
Total Haloacetic Acids (HAA5)
3.665 µg/L 6.1%
of the EPA limit 60 µg/L
worst single sample: 3.7 µg/L
8/12 SYR4 2018–2019
Chloroform
4.62 µg/L
No EPA limit set
worst single sample: 4.8 µg/L
5/12 SYR4 2018–2019
Dichloroacetic Acid
2.385 µg/L
No EPA limit set
worst single sample: 2.4 µg/L
4/12 SYR4 2018–2019
3 contaminants tested, none detected
Monobromoacetic AcidMonochloroacetic AcidTrichloroacetic Acid

Utility contact

Contact
CARLSON, CURTIS
Phone
401-268-6003
Email
[email protected]

Frequently asked questions about Exeter Job Corps Center

Is Exeter Job Corps Center tap water safe to drink?

EPA monitoring detected 11 contaminants in Exeter Job Corps Center's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Exeter Job Corps Center's water?

EPA monitoring detected Copper, Lead, Lead, Dibromochloromethane, TTHM, and others. The full list with the level and data source for each is above.

How many people does Exeter Job Corps Center serve?

Exeter Job Corps Center reports serving 300 people in Rhode Island, per its EPA record.

Has Exeter Job Corps Center had any water quality violations?

The EPA has 58 violations on file for Exeter Job Corps Center, of which 3 are health-based (a contaminant limit or required treatment was breached) and 7 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.