Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| TT | Health-based | Unaddressed | 2025-08-23 |
| TT | Health-based | Unaddressed | 2025-08-23 |
| TT | Health-based | Unaddressed | 2025-08-23 |
| MCL | Health-based | Resolved | 2008-10-01 → 2008-12-31 |
| MCL | Health-based | Resolved | 2008-10-01 → 2008-12-31 |
| MCL | Health-based | Resolved | 2008-10-01 → 2008-12-31 |
| MCL | Health-based | Resolved | 2008-10-01 → 2008-12-31 |
| MCL | Health-based | Resolved | 2008-10-01 → 2008-12-31 |
| Other | Monitoring | Resolved | 2022-07-01 |
| Other | Monitoring | Resolved | 2022-07-01 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate | 4570 µg/L 46% of the EPA limit 10000 µg/L
worst single sample: 4600 µg/L | 48/48 | SYR4 | 2012–2019 |
| Lead | 0.0270 mg/L 180% above the EPA limit of 0.0150 mg/L | 18/18 | LCR | 2025 |
| Nitrate-Nitrite | 4093.5 µg/L 41% of the EPA limit 10000 µg/L
worst single sample: 4160 µg/L | 8/8 | SYR4 | 2013–2019 |
| Copper | 832.6 µg/L 64% of the EPA limit 1300 µg/L
worst single sample: 850 µg/L | 5/5 | SYR4 | 2012 |
| Lead | 4.8 µg/L 32% of the EPA limit 15 µg/L
worst single sample: 5 µg/L | 5/5 | SYR4 | 2012 |
| Barium | 10.9 µg/L 0.5% of the EPA limit 2000 µg/L
worst single sample: 11 µg/L | 3/3 | SYR4 | 2013–2019 |
| Fluoride | 139 µg/L 3.5% of the EPA limit 4000 µg/L
worst single sample: 140 µg/L | 2/3 | SYR4 | 2013–2019 |
| Chromium | 8 µg/L 8% of the EPA limit 100 µg/L | 1/3 | SYR4 | 2013–2019 |
56 contaminants tested, none detected
Utility contact
Frequently asked questions about Jemp 1 Llc
Is Jemp 1 Llc tap water safe to drink?
EPA monitoring detected 8 contaminants in Jemp 1 Llc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Jemp 1 Llc's water?
EPA monitoring detected Nitrate, Lead, Nitrate-Nitrite, Copper, Lead, and others. The full list with the level and data source for each is above.
How many people does Jemp 1 Llc serve?
Jemp 1 Llc reports serving 28 people in Massachusetts, per its EPA record.
Has Jemp 1 Llc had any water quality violations?
The EPA has 74 violations on file for Jemp 1 Llc, of which 8 are health-based (a contaminant limit or required treatment was breached) and 3 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.