← Rhode Island

Tap water quality report

Woonsocket Water Division

EPA monitoring tested this supplier for 105 contaminants and detected 24. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

105
contaminants tested
24
detected
45,828
people served
37
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Providence

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

37
health-based violations
133
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2019-12-01 → 2019-12-31
TT Health-based Resolved 2019-12-01 → 2019-12-31
TT Health-based Resolved 2019-12-01 → 2019-12-31
TT Health-based Resolved 2019-12-01 → 2019-12-31
TT Health-based Resolved 2019-12-01 → 2019-12-31
TT Health-based Resolved 1996-07-01 → 1996-07-31
TT Health-based Resolved 1996-07-01 → 1996-07-31
TT Health-based Resolved 1996-07-01 → 1996-07-31
TT Health-based Resolved 1996-07-01 → 1996-07-31
TT Health-based Resolved 1996-07-01 → 1996-07-31

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
Pfpea 0.0075 µg/L 3/4 2023
Pfhxa 0.0050 µg/L 2/4 2023
Pfba 0.0067 µg/L 1/4 2023
Pfhpa 0.0037 µg/L 1/4 2023
PFOA 0.0058 µg/L 1/4 2023

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
TTHM
67.955 µg/L 85%
of the EPA limit 80 µg/L
worst single sample: 83.2 µg/L
128/128 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
25.5 µg/L 43%
of the EPA limit 60 µg/L
worst single sample: 34.9 µg/L
124/128 SYR4 2012–2019
Nitrate
550 µg/L 5.5%
of the EPA limit 10000 µg/L
worst single sample: 610 µg/L
44/52 SYR4 2012–2019
Bromodichloromethane
19.12 µg/L
No EPA limit set
worst single sample: 20 µg/L
32/32 SYR4 2017–2019
Copper
48.19 µg/L 3.7%
of the EPA limit 1300 µg/L
worst single sample: 66.8 µg/L
32/32 SYR4 2017
Chloroform
51.215 µg/L
No EPA limit set
worst single sample: 57.9 µg/L
32/32 SYR4 2017–2019
Dibromochloromethane
7.2 µg/L
No EPA limit set
worst single sample: 8.5 µg/L
32/32 SYR4 2017–2019
Dichloroacetic Acid
8.43 µg/L
No EPA limit set
worst single sample: 10.8 µg/L
32/32 SYR4 2017–2019
Lead
0.0066 mg/L 44%
of the EPA limit 0.0150 mg/L
32/32 LCR 2025
Trichloroacetic Acid
18.145 µg/L
No EPA limit set
worst single sample: 25.7 µg/L
32/32 SYR4 2017–2019
Barium
52.75 µg/L 2.6%
of the EPA limit 2000 µg/L
worst single sample: 55 µg/L
26/26 SYR4 2012–2019
Lead
4.095 µg/L 27%
of the EPA limit 15 µg/L
worst single sample: 4.5 µg/L
10/32 SYR4 2017
Di(2-ethylhexyl) Phthalate
1 µg/L 17%
of the EPA limit 6 µg/L
8/27 SYR4 2014–2019
Monochloroacetic Acid
4.36 µg/L
No EPA limit set
worst single sample: 4.5 µg/L
8/32 SYR4 2017–2019
Bromoform
0.6950 µg/L
No EPA limit set
worst single sample: 0.7000 µg/L
2/32 SYR4 2017–2019
Chromium
1 µg/L 1%
of the EPA limit 100 µg/L
2/26 SYR4 2012–2019
Nitrate-Nitrite
210 µg/L 2.1%
of the EPA limit 10000 µg/L
2/2 SYR4 2013
Nitrite
20 µg/L 2%
of the EPA limit 1000 µg/L
2/28 SYR4 2012–2019
Fluoride
320 µg/L 8%
of the EPA limit 4000 µg/L
1/26 SYR4 2012–2019
81 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined Radium (-226 And -228)DichloromethaneDalaponDi(2-ethylhexyl) AdipateDibromoacetic AcidDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidNetfosaaNfdhaNmefosaaOxamylPFBSPfdaPfdoaPfeesaPfhpsPFHXSPfmbaPfmpaPFNAPFOSPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
D'AGOSTINO, STEVE
Phone
401-767-1413
Email
[email protected]

Frequently asked questions about Woonsocket Water Division

Is Woonsocket Water Division tap water safe to drink?

EPA monitoring detected 24 contaminants in Woonsocket Water Division's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Woonsocket Water Division's water?

EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Nitrate, Bromodichloromethane, Copper, and others. The full list with the level and data source for each is above.

How many people does Woonsocket Water Division serve?

Woonsocket Water Division reports serving 45,828 people in Rhode Island, per its EPA record.

Has Woonsocket Water Division had any water quality violations?

The EPA has 133 violations on file for Woonsocket Water Division, of which 37 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.