← Pennsylvania

Tap water quality report

Dover Twp Water Sys

EPA monitoring tested this supplier for 110 contaminants and detected 25. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

110
contaminants tested
25
detected
21,097
people served
29
health-based violations
Water source
SWP
Ownership
Local government
Counties served
York

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

29
health-based violations
1,446
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2019-01-01 → 2019-01-31
TT Health-based Resolved 2019-01-01 → 2019-01-31
TT Health-based Resolved 2011-04-01 → 2011-04-30
TT Health-based Resolved 2011-04-01 → 2011-04-30
TT Health-based Resolved 2011-04-01 → 2011-04-30
MCL Health-based Resolved 2008-01-01 → 2008-03-31
MCL Health-based Resolved 2008-01-01 → 2008-03-31
MCL Health-based Resolved 2008-01-01 → 2008-03-31
MCL Health-based Resolved 2008-01-01 → 2008-03-31
MCL Health-based Resolved 2007-10-01 → 2007-10-31

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
PFBS 0.0057 µg/L 11/20 2025
PFOS 0.0096 µg/L 11/20 2025
PFOA 0.0059 µg/L 9/20 2025
Pfpea 0.0106 µg/L 7/20 2025
Pfhxa 0.0064 µg/L 2/20 2025
Pfhpa 0.0035 µg/L 1/20 2025

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
4324.5 µg/L 43%
of the EPA limit 10000 µg/L
worst single sample: 9200 µg/L
188/188 SYR4 2012–2019
Chloroform
30 µg/L
No EPA limit set
worst single sample: 40.8 µg/L
140/154 SYR4 2012–2019
Bromodichloromethane
8.26 µg/L
No EPA limit set
worst single sample: 9 µg/L
138/142 SYR4 2012–2019
Dibromochloromethane
2.515 µg/L
No EPA limit set
worst single sample: 4.8 µg/L
138/145 SYR4 2012–2019
TTHM
39.52 µg/L 49%
of the EPA limit 80 µg/L
worst single sample: 51.5 µg/L
128/130 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
30 µg/L 50%
of the EPA limit 60 µg/L
worst single sample: 50 µg/L
110/130 SYR4 2012–2019
Copper
962.5 µg/L 74%
of the EPA limit 1300 µg/L
worst single sample: 1260 µg/L
72/93 SYR4 2013–2019
Dichloroacetic Acid
19.2 µg/L
No EPA limit set
worst single sample: 32 µg/L
57/64 SYR4 2016–2019
Trichloroacetic Acid
14 µg/L
No EPA limit set
worst single sample: 18 µg/L
45/64 SYR4 2016–2019
Lead
0.0049 mg/L 33%
of the EPA limit 0.0150 mg/L
17/17 LCR 2025
Lithium
58.8 µg/L
No EPA limit set
15/20 UCMR-5 2025
Bromoform
0.8900 µg/L
No EPA limit set
worst single sample: 1 µg/L
12/134 SYR4 2012–2019
Lead
21 µg/L 140%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 22 µg/L
11/93 SYR4 2013–2019
Combined Uranium
11.616 µg/L 39%
of the EPA limit 30 µg/L
worst single sample: 12.7782 µg/L
9/9 SYR4 2012–2017
Trichloroethylene
1.78 µg/L 36%
of the EPA limit 5 µg/L
worst single sample: 1.8 µg/L
5/40 SYR4 2012–2019
Dibromoacetic Acid
1.85 µg/L
No EPA limit set
worst single sample: 2 µg/L
4/64 SYR4 2016–2019
Monochloroacetic Acid
3 µg/L
No EPA limit set
4/64 SYR4 2016–2019
Carbon Tetrachloride
0.7900 µg/L 16%
of the EPA limit 5 µg/L
worst single sample: 0.8000 µg/L
3/40 SYR4 2012–2019
Fluoride
236 µg/L 5.9%
of the EPA limit 4000 µg/L
worst single sample: 240 µg/L
3/25 SYR4 2012–2018
85 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,3,7,8-TCDD2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBariumBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPfdaPfdoaPfeesaPfhpsPFHXSPfmbaPfmpaPFNAPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
LAUREL OSWALT
Phone
717-292-3634

Frequently asked questions about Dover Twp Water Sys

Is Dover Twp Water Sys tap water safe to drink?

EPA monitoring detected 25 contaminants in Dover Twp Water Sys's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Dover Twp Water Sys's water?

EPA monitoring detected Nitrate, Chloroform, Bromodichloromethane, Dibromochloromethane, TTHM, and others. The full list with the level and data source for each is above.

How many people does Dover Twp Water Sys serve?

Dover Twp Water Sys reports serving 21,097 people in Pennsylvania, per its EPA record.

Has Dover Twp Water Sys had any water quality violations?

The EPA has 1446 violations on file for Dover Twp Water Sys, of which 29 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.