Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| Other | Monitoring | Resolved | 2002-07-01 → 2002-07-12 |
| Other | Monitoring | Resolved | 2001-07-01 → 2001-07-23 |
PFAS detected
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate | 5200 µg/L 52% of the EPA limit 10000 µg/L
worst single sample: 5300 µg/L | 136/138 | SYR4 | 2012–2019 |
| Copper | 973 µg/L 75% of the EPA limit 1300 µg/L
worst single sample: 1400 µg/L | 64/64 | SYR4 | 2013–2019 |
| Lead | 6.425 µg/L 43% of the EPA limit 15 µg/L
worst single sample: 12 µg/L | 28/64 | SYR4 | 2013–2019 |
| Barium | 223 µg/L 11% of the EPA limit 2000 µg/L
worst single sample: 240 µg/L | 18/18 | SYR4 | 2012–2018 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 15/15 | LCR | 2025 |
| Bromodichloromethane | 5.84 µg/L No EPA limit set
worst single sample: 5.9 µg/L | 13/14 | SYR4 | 2013–2019 |
| Chloroform | 4.766 µg/L No EPA limit set
worst single sample: 5.9 µg/L | 13/14 | SYR4 | 2013–2019 |
| Dibromochloromethane | 5.579 µg/L No EPA limit set
worst single sample: 5.7 µg/L | 12/14 | SYR4 | 2013–2019 |
| TTHM | 15.44 µg/L 19% of the EPA limit 80 µg/L
worst single sample: 16.1 µg/L | 12/14 | SYR4 | 2013–2019 |
| Lithium | 30.2 µg/L No EPA limit set | 10/12 | UCMR-5 | 2024 |
| Arsenic | 6.2 µg/L 62% of the EPA limit 10 µg/L
worst single sample: 6.6 µg/L | 9/18 | SYR4 | 2012–2018 |
| Bromoform | 3.12 µg/L No EPA limit set
worst single sample: 3.51 µg/L | 7/14 | SYR4 | 2013–2019 |
| Total Haloacetic Acids (HAA5) | 5.925 µg/L 9.9% of the EPA limit 60 µg/L
worst single sample: 6.7 µg/L | 6/13 | SYR4 | 2013–2019 |
| Trichloroethylene | 3.04 µg/L 61% of the EPA limit 5 µg/L
worst single sample: 3.1 µg/L | 5/68 | SYR4 | 2012–2019 |
| Chromium | 1.29 µg/L 1.3% of the EPA limit 100 µg/L
worst single sample: 1.3 µg/L | 2/18 | SYR4 | 2012–2018 |
| Ethylbenzene | 0.7806 µg/L 0.1% of the EPA limit 700 µg/L
worst single sample: 0.7950 µg/L | 2/64 | SYR4 | 2012–2019 |
| Fluoride | 138.5 µg/L 3.5% of the EPA limit 4000 µg/L
worst single sample: 140 µg/L | 2/18 | SYR4 | 2012–2018 |
| Selenium | 1.48 µg/L 3% of the EPA limit 50 µg/L
worst single sample: 1.5 µg/L | 2/18 | SYR4 | 2012–2018 |
| Xylenes, Total | 1.685 µg/L 0% of the EPA limit 10000 µg/L
worst single sample: 1.69 µg/L | 2/64 | SYR4 | 2012–2019 |
| Cyanide | 5 µg/L 2.5% of the EPA limit 200 µg/L | 1/18 | SYR4 | 2012–2018 |
80 contaminants tested, none detected
Utility contact
Frequently asked questions about Veolia Newberry
Is Veolia Newberry tap water safe to drink?
EPA monitoring detected 28 contaminants in Veolia Newberry's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Veolia Newberry's water?
EPA monitoring detected Nitrate, Copper, Lead, Barium, Lead, and others. The full list with the level and data source for each is above.
How many people does Veolia Newberry serve?
Veolia Newberry reports serving 6,480 people in Pennsylvania, per its EPA record.
Has Veolia Newberry had any water quality violations?
The EPA has 2 violations on file for Veolia Newberry, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.