Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| TT | Health-based | Resolved | 2021-11-27 |
| TT | Health-based | Resolved | 2021-11-27 |
| TT | Health-based | Resolved | 2021-11-27 |
| TT | Health-based | Resolved | 2021-11-27 |
| MON | Monitoring | Resolved | 2024-12-01 → 2024-12-31 |
| MON | Monitoring | Resolved | 2024-12-01 → 2024-12-31 |
| MON | Monitoring | Resolved | 2024-12-01 → 2024-12-31 |
| MON | Monitoring | Resolved | 2024-11-01 → 2024-11-30 |
| MON | Monitoring | Resolved | 2024-11-01 → 2024-11-30 |
| MON | Monitoring | Resolved | 2024-11-01 → 2024-11-30 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Bromodichloromethane | 7.45 µg/L No EPA limit set
worst single sample: 9.5 µg/L | 196/196 | SYR4 | 2012–2019 |
| Chloroform | 67.125 µg/L No EPA limit set
worst single sample: 109 µg/L | 196/196 | SYR4 | 2012–2019 |
| TTHM | 72.6 µg/L 91% of the EPA limit 80 µg/L
worst single sample: 118 µg/L | 196/196 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 37.775 µg/L 63% of the EPA limit 60 µg/L
worst single sample: 65 µg/L | 196/196 | SYR4 | 2012–2019 |
| Copper | 84.6 µg/L 6.5% of the EPA limit 1300 µg/L
worst single sample: 110 µg/L | 109/124 | SYR4 | 2013–2019 |
| Dibromochloromethane | 1.3 µg/L No EPA limit set
worst single sample: 2 µg/L | 81/196 | SYR4 | 2012–2019 |
| Lead | 40.2 µg/L 268% of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 160.82 µg/L | 29/124 | SYR4 | 2013–2019 |
| Dichloroacetic Acid | 22.04 µg/L No EPA limit set
worst single sample: 24.3 µg/L | 25/25 | SYR4 | 2018–2019 |
| Trichloroacetic Acid | 13.54 µg/L No EPA limit set
worst single sample: 13.6 µg/L | 25/25 | SYR4 | 2018–2019 |
| Nitrate | 480 µg/L 4.8% of the EPA limit 10000 µg/L | 14/16 | SYR4 | 2012–2019 |
| Lead | 0.0071 mg/L 47% of the EPA limit 0.0150 mg/L | 12/12 | LCR | 2025 |
| Monochloroacetic Acid | 3.46 µg/L No EPA limit set
worst single sample: 3.5 µg/L | 9/25 | SYR4 | 2018–2019 |
| Barium | 14 µg/L 0.7% of the EPA limit 2000 µg/L | 8/8 | SYR4 | 2012–2019 |
| Fluoride | 972 µg/L 24% of the EPA limit 4000 µg/L
worst single sample: 1000 µg/L | 8/8 | SYR4 | 2012–2019 |
| Monobromoacetic Acid | 2.16 µg/L No EPA limit set
worst single sample: 2.2 µg/L | 2/25 | SYR4 | 2018–2019 |
| Dalapon | 55.8 µg/L 28% of the EPA limit 200 µg/L | 1/13 | SYR4 | 2012–2019 |
| Hexachlorocyclopentadiene | 0.2600 µg/L 0.5% of the EPA limit 50 µg/L | 1/11 | SYR4 | 2012–2019 |
| Nitrite | 240 µg/L 24% of the EPA limit 1000 µg/L | 1/8 | SYR4 | 2012–2019 |
91 contaminants tested, none detected
Utility contact
Frequently asked questions about Lebanon Water Auth
Is Lebanon Water Auth tap water safe to drink?
EPA monitoring detected 18 contaminants in Lebanon Water Auth's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Lebanon Water Auth's water?
EPA monitoring detected Bromodichloromethane, Chloroform, TTHM, Total Haloacetic Acids (HAA5), Copper, and others. The full list with the level and data source for each is above.
How many people does Lebanon Water Auth serve?
Lebanon Water Auth reports serving 57,000 people in Pennsylvania, per its EPA record.
Has Lebanon Water Auth had any water quality violations?
The EPA has 83 violations on file for Lebanon Water Auth, of which 4 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.