Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MR | Monitoring | Resolved | 2024-08-01 → 2024-08-31 |
| MR | Monitoring | Resolved | 2024-08-01 → 2024-08-31 |
| MR | Monitoring | Resolved | 2024-08-01 → 2024-08-31 |
| MR | Monitoring | Resolved | 2024-08-01 → 2024-08-31 |
| Other | Monitoring | Resolved | 2024-04-11 |
| Other | Monitoring | Resolved | 2024-04-11 |
| Other | Monitoring | Resolved | 2024-04-11 |
| Other | Monitoring | Resolved | 2024-04-11 |
| Other | Monitoring | Resolved | 2024-04-11 |
| Other | Monitoring | Resolved | 2024-04-11 |
PFAS detected
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Chloroform | 57.46 µg/L No EPA limit set
worst single sample: 162 µg/L | 129/130 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 56.32 µg/L 94% of the EPA limit 60 µg/L
worst single sample: 64.1 µg/L | 129/130 | SYR4 | 2012–2019 |
| Bromodichloromethane | 14 µg/L No EPA limit set
worst single sample: 18.3 µg/L | 128/130 | SYR4 | 2012–2019 |
| TTHM | 72.065 µg/L 90% of the EPA limit 80 µg/L
worst single sample: 183 µg/L | 128/130 | SYR4 | 2012–2019 |
| Dibromochloromethane | 4.395 µg/L No EPA limit set
worst single sample: 6.2 µg/L | 104/130 | SYR4 | 2012–2019 |
| Copper | 103 µg/L 7.9% of the EPA limit 1300 µg/L
worst single sample: 190 µg/L | 91/92 | SYR4 | 2013–2019 |
| Nitrate | 4785 µg/L 48% of the EPA limit 10000 µg/L
worst single sample: 5000 µg/L | 64/64 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 21.93 µg/L No EPA limit set
worst single sample: 22.5 µg/L | 20/20 | SYR4 | 2018–2019 |
| Trichloroacetic Acid | 18.69 µg/L No EPA limit set
worst single sample: 20.4 µg/L | 20/20 | SYR4 | 2018–2019 |
| Lead | 0.0026 mg/L 17% of the EPA limit 0.0150 mg/L | 14/14 | LCR | 2025 |
| Lead | 22 µg/L 147% of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 26 µg/L | 9/92 | SYR4 | 2013–2019 |
| Barium | 40.3 µg/L 2% of the EPA limit 2000 µg/L
worst single sample: 41 µg/L | 8/8 | SYR4 | 2012–2019 |
| Fluoride | 586 µg/L 15% of the EPA limit 4000 µg/L
worst single sample: 600 µg/L | 8/8 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 1.455 µg/L No EPA limit set
worst single sample: 1.5 µg/L | 4/20 | SYR4 | 2018–2019 |
| Monobromoacetic Acid | 2.83 µg/L No EPA limit set
worst single sample: 2.9 µg/L | 2/20 | SYR4 | 2018–2019 |
| Monochloroacetic Acid | 2.7 µg/L No EPA limit set | 2/20 | SYR4 | 2018–2019 |
| Atrazine | 0.2800 µg/L 9.3% of the EPA limit 3 µg/L | 1/9 | SYR4 | 2012–2018 |
| Cyanide | 2.6 µg/L 1.3% of the EPA limit 200 µg/L | 1/8 | SYR4 | 2012–2019 |
86 contaminants tested, none detected
Utility contact
Frequently asked questions about Carlisle Water Trmt Plt
Is Carlisle Water Trmt Plt tap water safe to drink?
EPA monitoring detected 24 contaminants in Carlisle Water Trmt Plt's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Carlisle Water Trmt Plt's water?
EPA monitoring detected Chloroform, Total Haloacetic Acids (HAA5), Bromodichloromethane, TTHM, Dibromochloromethane, and others. The full list with the level and data source for each is above.
How many people does Carlisle Water Trmt Plt serve?
Carlisle Water Trmt Plt reports serving 26,000 people in Pennsylvania, per its EPA record.
Has Carlisle Water Trmt Plt had any water quality violations?
The EPA has 75 violations on file for Carlisle Water Trmt Plt, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.