Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Archived | 1985-08-26 → 1985-10-25 |
| MON | Monitoring | Resolved | 2025-04-01 → 2025-04-30 |
| MON | Monitoring | Resolved | 2025-04-01 → 2025-04-30 |
| MON | Monitoring | Resolved | 2025-04-01 → 2025-04-30 |
| MON | Monitoring | Resolved | 2025-04-01 → 2025-04-30 |
| MR | Monitoring | Resolved | 2024-10-01 → 2024-12-31 |
| MR | Monitoring | Resolved | 2024-10-01 → 2024-12-31 |
| MR | Monitoring | Resolved | 2024-10-01 → 2024-12-31 |
| MR | Monitoring | Resolved | 2024-10-01 → 2024-12-31 |
| MR | Monitoring | Resolved | 2024-10-01 → 2024-12-31 |
PFAS detected
| Contaminant | Max | Detection rate | Period |
|---|---|---|---|
| PFBS | 0.0150 µg/L | 4/4 | 2023 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 236.4 µg/L 18% of the EPA limit 1300 µg/L
worst single sample: 909 µg/L | 55/60 | SYR4 | 2013–2019 |
| Bromodichloromethane | 6.38 µg/L No EPA limit set
worst single sample: 7.1 µg/L | 52/52 | SYR4 | 2012–2019 |
| Chloroform | 37.535 µg/L No EPA limit set
worst single sample: 44.9 µg/L | 52/52 | SYR4 | 2012–2019 |
| TTHM | 43.09 µg/L 54% of the EPA limit 80 µg/L
worst single sample: 51.9 µg/L | 52/52 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 46.865 µg/L 78% of the EPA limit 60 µg/L
worst single sample: 50.6 µg/L | 42/52 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 14.7 µg/L No EPA limit set
worst single sample: 20.4 µg/L | 40/50 | SYR4 | 2013–2019 |
| Dibromochloromethane | 1.4295 µg/L No EPA limit set
worst single sample: 1.85 µg/L | 38/52 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 29.6 µg/L No EPA limit set
worst single sample: 31.9 µg/L | 32/50 | SYR4 | 2013–2019 |
| Lead | 0.0010 mg/L 6.9% of the EPA limit 0.0150 mg/L | 13/13 | LCR | 2025 |
| Lead | 38.38 µg/L 256% of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 69.9 µg/L | 11/60 | SYR4 | 2013–2019 |
| Barium | 40.625 µg/L 2% of the EPA limit 2000 µg/L
worst single sample: 42.9 µg/L | 8/8 | SYR4 | 2012–2019 |
| Monochloroacetic Acid | 4.392 µg/L No EPA limit set
worst single sample: 4.47 µg/L | 5/50 | SYR4 | 2013–2019 |
| Selenium | 2.45 µg/L 4.9% of the EPA limit 50 µg/L | 1/8 | SYR4 | 2012–2019 |
96 contaminants tested, none detected
Utility contact
Frequently asked questions about Derry Boro Muni Auth
Is Derry Boro Muni Auth tap water safe to drink?
EPA monitoring detected 14 contaminants in Derry Boro Muni Auth's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Derry Boro Muni Auth's water?
EPA monitoring detected Copper, Bromodichloromethane, Chloroform, TTHM, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.
How many people does Derry Boro Muni Auth serve?
Derry Boro Muni Auth reports serving 6,500 people in Pennsylvania, per its EPA record.
Has Derry Boro Muni Auth had any water quality violations?
The EPA has 335 violations on file for Derry Boro Muni Auth, of which 1 is health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.