← Pennsylvania

Tap water quality report

Pa American Water Co-Indiana D

EPA monitoring tested this supplier for 106 contaminants and detected 14. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

106
contaminants tested
14
detected
22,360
people served
0
health-based violations
Water source
Surface water
Ownership
Private
Counties served
Indiana

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
7
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2015-08-01 → 2015-08-31
MR Monitoring Resolved 2015-08-01 → 2015-08-31
MR Monitoring Resolved 2015-08-01 → 2015-08-31
MR Monitoring Resolved 2015-08-01 → 2015-08-31
MR Monitoring Resolved 2015-08-01 → 2015-08-31
MR Monitoring Resolved 2007-10-01 → 2007-10-31
Other Monitoring Resolved 2000-07-01 → 2000-07-21

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
14.98 µg/L
No EPA limit set
worst single sample: 18.4 µg/L
133/133 SYR4 2012–2019
Chloroform
91.04 µg/L
No EPA limit set
worst single sample: 114.7 µg/L
133/133 SYR4 2012–2019
Dibromochloromethane
3.86 µg/L
No EPA limit set
worst single sample: 5.3 µg/L
133/133 SYR4 2012–2019
TTHM
106.38 µg/L 133%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 127.1 µg/L
133/133 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
65.86 µg/L 110%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 111.2 µg/L
133/133 SYR4 2012–2019
Copper
59.8 µg/L 4.6%
of the EPA limit 1300 µg/L
worst single sample: 93 µg/L
47/90 SYR4 2013–2019
Lead
6 µg/L 40%
of the EPA limit 15 µg/L
worst single sample: 17 µg/L
25/90 SYR4 2013–2019
Dichloroacetic Acid
19.305 µg/L
No EPA limit set
worst single sample: 19.4 µg/L
20/20 SYR4 2018–2019
Trichloroacetic Acid
22.03 µg/L
No EPA limit set
worst single sample: 22.6 µg/L
20/20 SYR4 2018–2019
Nitrate
1170 µg/L 12%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
13/13 LCR 2025
Fluoride
740 µg/L 19%
of the EPA limit 4000 µg/L
8/8 SYR4 2012–2019
Atrazine
0.9750 µg/L 33%
of the EPA limit 3 µg/L
worst single sample: 1 µg/L
6/12 SYR4 2014–2019
Lithium
13.5 µg/L
No EPA limit set
4/4 UCMR-5 2024
92 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicBhc-GammaBariumBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
JON NATALE
Phone
724-463-8704

Frequently asked questions about Pa American Water Co-Indiana D

Is Pa American Water Co-Indiana D tap water safe to drink?

EPA monitoring detected 14 contaminants in Pa American Water Co-Indiana D's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Pa American Water Co-Indiana D's water?

EPA monitoring detected Bromodichloromethane, Chloroform, Dibromochloromethane, TTHM, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.

How many people does Pa American Water Co-Indiana D serve?

Pa American Water Co-Indiana D reports serving 22,360 people in Pennsylvania, per its EPA record.

Has Pa American Water Co-Indiana D had any water quality violations?

The EPA has 7 violations on file for Pa American Water Co-Indiana D, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.