Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2024-04-01 → 2024-06-30 |
| MCL | Health-based | Resolved | 2024-04-01 → 2024-06-30 |
| MCL | Health-based | Resolved | 2024-04-01 → 2024-06-30 |
| MCL | Health-based | Resolved | 2024-04-01 → 2024-06-30 |
| MCL | Health-based | Resolved | 2024-01-01 → 2024-03-31 |
| MCL | Health-based | Resolved | 2024-01-01 → 2024-03-31 |
| MCL | Health-based | Resolved | 2024-01-01 → 2024-03-31 |
| MCL | Health-based | Resolved | 2024-01-01 → 2024-03-31 |
| MCL | Health-based | Resolved | 2023-10-01 → 2023-12-31 |
| MCL | Health-based | Resolved | 2023-10-01 → 2023-12-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| TTHM | 134.5 µg/L 168% of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 155.5 µg/L | 32/32 | SYR4 | 2012–2019 |
| Bromodichloromethane | 39.05 µg/L No EPA limit set
worst single sample: 44 µg/L | 31/31 | SYR4 | 2012–2019 |
| Chloroform | 84.35 µg/L No EPA limit set
worst single sample: 91 µg/L | 31/31 | SYR4 | 2012–2019 |
| Dibromochloromethane | 22.5 µg/L No EPA limit set
worst single sample: 43.6 µg/L | 31/31 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 72.65 µg/L 121% of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 92.4 µg/L | 31/32 | SYR4 | 2012–2019 |
| Copper | 634.45 µg/L 49% of the EPA limit 1300 µg/L
worst single sample: 1400 µg/L | 30/30 | SYR4 | 2013–2019 |
| Lead | 7.7 µg/L 51% of the EPA limit 15 µg/L
worst single sample: 8 µg/L | 21/30 | SYR4 | 2013–2019 |
| Nitrate | 1700 µg/L 17% of the EPA limit 10000 µg/L | 12/12 | SYR4 | 2012–2019 |
| Bromoform | 6.645 µg/L No EPA limit set
worst single sample: 9.89 µg/L | 11/32 | SYR4 | 2012–2019 |
| Barium | 41.85 µg/L 2.1% of the EPA limit 2000 µg/L
worst single sample: 43.5 µg/L | 7/7 | SYR4 | 2012–2019 |
| Dalapon | 1.624 µg/L 0.8% of the EPA limit 200 µg/L
worst single sample: 1.67 µg/L | 5/10 | SYR4 | 2014–2019 |
| Dibromoacetic Acid | 1200.4 µg/L No EPA limit set
worst single sample: 1500 µg/L | 5/6 | SYR4 | 2018–2019 |
| Dichloroacetic Acid | 23.76 µg/L No EPA limit set
worst single sample: 24.7 µg/L | 5/5 | SYR4 | 2018–2019 |
| Trichloroacetic Acid | 39.28 µg/L No EPA limit set
worst single sample: 44.1 µg/L | 5/5 | SYR4 | 2018–2019 |
| Lead | 0.0030 mg/L 20% of the EPA limit 0.0150 mg/L | 4/4 | LCR | 1998 |
| Monobromoacetic Acid | 2125.42 µg/L No EPA limit set
worst single sample: 2500 µg/L | 4/6 | SYR4 | 2018–2019 |
| Monochloroacetic Acid | 1955.37 µg/L No EPA limit set
worst single sample: 2300 µg/L | 4/6 | SYR4 | 2018–2019 |
| Dichloromethane | 0.7580 µg/L 15% of the EPA limit 5 µg/L | 1/10 | SYR4 | 2012–2019 |
| Toluene | 0.7940 µg/L 0.1% of the EPA limit 1000 µg/L | 1/10 | SYR4 | 2012–2019 |
60 contaminants tested, none detected
Utility contact
Frequently asked questions about Midland Boro Muni Auth
Is Midland Boro Muni Auth tap water safe to drink?
EPA monitoring detected 19 contaminants in Midland Boro Muni Auth's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Midland Boro Muni Auth's water?
EPA monitoring detected TTHM, Bromodichloromethane, Chloroform, Dibromochloromethane, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.
How many people does Midland Boro Muni Auth serve?
Midland Boro Muni Auth reports serving 3,100 people in Pennsylvania, per its EPA record.
Has Midland Boro Muni Auth had any water quality violations?
The EPA has 926 violations on file for Midland Boro Muni Auth, of which 159 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.