← Pennsylvania

Tap water quality report

Center Twp Water Auth

EPA monitoring tested this supplier for 109 contaminants and detected 17. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

109
contaminants tested
17
detected
19,000
people served
14
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Beaver

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

14
health-based violations
515
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2017-02-01 → 2017-02-28
TT Health-based Resolved 2017-02-01 → 2017-02-28
TT Health-based Resolved 2017-02-01 → 2017-02-28
TT Health-based Resolved 2017-02-01 → 2017-02-28
TT Health-based Resolved 2016-09-01 → 2016-09-30
TT Health-based Resolved 2016-09-01 → 2016-09-30
TT Health-based Resolved 2016-09-01 → 2016-09-30
TT Health-based Resolved 2016-09-01 → 2016-09-30
TT Health-based Resolved 2016-09-01 → 2016-09-30
TT Health-based Resolved 2016-09-01 → 2016-09-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
2351 µg/L 181%
of the EPA limit, at the 95th percentile of samples — 1300 µg/L
worst single sample: 3570 µg/L
399/399 SYR4 2013–2019
Lead
19.17 µg/L 128%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 28.6 µg/L
75/286 SYR4 2013–2019
Bromodichloromethane
22.445 µg/L
No EPA limit set
worst single sample: 28.1 µg/L
60/60 SYR4 2012–2019
Chloroform
37.21 µg/L
No EPA limit set
worst single sample: 55 µg/L
60/60 SYR4 2012–2019
Dibromochloromethane
19.05 µg/L
No EPA limit set
worst single sample: 23.2 µg/L
60/60 SYR4 2012–2019
TTHM
70.525 µg/L 88%
of the EPA limit 80 µg/L
worst single sample: 93 µg/L
60/60 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
24 µg/L 40%
of the EPA limit 60 µg/L
worst single sample: 29 µg/L
58/60 SYR4 2012–2019
Bromoform
7.009 µg/L
No EPA limit set
worst single sample: 9.5 µg/L
44/60 SYR4 2012–2019
Dichloroacetic Acid
14.7 µg/L
No EPA limit set
worst single sample: 16 µg/L
24/24 SYR4 2018–2019
Trichloroacetic Acid
11 µg/L
No EPA limit set
worst single sample: 12 µg/L
24/24 SYR4 2018–2019
Dibromoacetic Acid
3.9 µg/L
No EPA limit set
worst single sample: 4 µg/L
22/24 SYR4 2018–2019
Nitrate
1000 µg/L 10%
of the EPA limit 10000 µg/L
20/26 SYR4 2012–2019
Lead
0.0014 mg/L 9.2%
of the EPA limit 0.0150 mg/L
15/15 LCR 2025
Monochloroacetic Acid
2.678 µg/L
No EPA limit set
worst single sample: 2.9 µg/L
7/24 SYR4 2018–2019
Barium
132.4 µg/L 6.6%
of the EPA limit 2000 µg/L
worst single sample: 138 µg/L
5/5 SYR4 2012–2019
Monobromoacetic Acid
0.8292 µg/L
No EPA limit set
worst single sample: 0.8700 µg/L
4/24 SYR4 2018–2019
Selenium
9.13 µg/L 18%
of the EPA limit 50 µg/L
worst single sample: 9.3 µg/L
2/5 SYR4 2012–2019
92 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,3,7,8-TCDD2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneFluorideGlyphosateGross Beta Particle ActivityHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
WILLIAM DICIOCCIO
Phone
724-774-7766

Frequently asked questions about Center Twp Water Auth

Is Center Twp Water Auth tap water safe to drink?

EPA monitoring detected 17 contaminants in Center Twp Water Auth's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Center Twp Water Auth's water?

EPA monitoring detected Copper, Lead, Bromodichloromethane, Chloroform, Dibromochloromethane, and others. The full list with the level and data source for each is above.

How many people does Center Twp Water Auth serve?

Center Twp Water Auth reports serving 19,000 people in Pennsylvania, per its EPA record.

Has Center Twp Water Auth had any water quality violations?

The EPA has 515 violations on file for Center Twp Water Auth, of which 14 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.