Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| TT | Health-based | Resolved | 2021-01-01 |
| TT | Health-based | Resolved | 2021-01-01 |
| TT | Health-based | Resolved | 2021-01-01 |
| TT | Health-based | Resolved | 2021-01-01 |
| TT | Health-based | Resolved | 2017-06-01 → 2017-06-30 |
| TT | Health-based | Resolved | 2017-06-01 → 2017-06-30 |
| TT | Health-based | Resolved | 2017-06-01 → 2017-06-30 |
| TT | Health-based | Resolved | 2017-06-01 → 2017-06-30 |
| MR | Monitoring | Resolved | 2026-03-01 → 2026-03-31 |
| MR | Monitoring | Resolved | 2026-03-01 → 2026-03-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate | 6720 µg/L 67% of the EPA limit 10000 µg/L
worst single sample: 6880 µg/L | 88/88 | SYR4 | 2012–2019 |
| Copper | 120 µg/L 9.2% of the EPA limit 1300 µg/L
worst single sample: 330 µg/L | 50/50 | SYR4 | 2012–2019 |
| Lead | 13.085 µg/L 87% of the EPA limit 15 µg/L
worst single sample: 31 µg/L | 28/50 | SYR4 | 2012–2019 |
| Bromodichloromethane | 5.9575 µg/L No EPA limit set
worst single sample: 6.18 µg/L | 24/28 | SYR4 | 2012–2019 |
| Chloroform | 11.23 µg/L No EPA limit set
worst single sample: 12.1 µg/L | 24/28 | SYR4 | 2012–2019 |
| TTHM | 20.29 µg/L 25% of the EPA limit 80 µg/L
worst single sample: 23.1 µg/L | 23/28 | SYR4 | 2012–2019 |
| Dibromochloromethane | 3.092 µg/L No EPA limit set
worst single sample: 3.33 µg/L | 18/28 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 8.665 µg/L 14% of the EPA limit 60 µg/L
worst single sample: 9.58 µg/L | 7/28 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 7.354 µg/L No EPA limit set
worst single sample: 7.56 µg/L | 5/24 | SYR4 | 2014–2019 |
| Lead | 0.0200 mg/L 133% above the EPA limit of 0.0150 mg/L | 4/4 | LCR | 2003 |
| Trichloroacetic Acid | 2.1715 µg/L No EPA limit set
worst single sample: 2.2 µg/L | 4/24 | SYR4 | 2014–2019 |
| Barium | 32.73 µg/L 1.6% of the EPA limit 2000 µg/L
worst single sample: 34 µg/L | 2/6 | SYR4 | 2012–2018 |
| Beryllium, Total | 2.13 µg/L 53% of the EPA limit 4 µg/L | 1/6 | SYR4 | 2012–2018 |
| Bromoform | 2.2 µg/L No EPA limit set | 1/28 | SYR4 | 2012–2019 |
66 contaminants tested, none detected
Utility contact
Frequently asked questions about Selinsgrove Center
Is Selinsgrove Center tap water safe to drink?
EPA monitoring detected 14 contaminants in Selinsgrove Center's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Selinsgrove Center's water?
EPA monitoring detected Nitrate, Copper, Lead, Bromodichloromethane, Chloroform, and others. The full list with the level and data source for each is above.
How many people does Selinsgrove Center serve?
Selinsgrove Center reports serving 1,000 people in Pennsylvania, per its EPA record.
Has Selinsgrove Center had any water quality violations?
The EPA has 630 violations on file for Selinsgrove Center, of which 8 are health-based (a contaminant limit or required treatment was breached) and 3 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.