← Pennsylvania

Tap water quality report

Pa American White Deer

EPA monitoring tested this supplier for 106 contaminants and detected 13. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

106
contaminants tested
13
detected
30,209
people served
0
health-based violations
Water source
Surface water
Ownership
Private
Counties served
Northumberland

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
7
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2006-10-01 → 2006-10-31
MR Monitoring Resolved 2006-10-01 → 2006-10-31
MR Monitoring Resolved 2005-07-01 → 2005-09-30
Other Monitoring Resolved 2001-07-01 → 2001-07-23
Other Monitoring Resolved 2000-07-01 → 2000-07-10
MR Monitoring Resolved 1990-12-01 → 1990-12-31
MR Monitoring Resolved 1990-12-01 → 1990-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
19 µg/L
No EPA limit set
worst single sample: 33.4 µg/L
161/161 SYR4 2012–2019
Chloroform
48.7 µg/L
No EPA limit set
worst single sample: 68.4 µg/L
161/161 SYR4 2012–2019
TTHM
79.5 µg/L 99%
of the EPA limit 80 µg/L
worst single sample: 119.3 µg/L
161/161 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
35 µg/L 58%
of the EPA limit 60 µg/L
worst single sample: 43.4 µg/L
161/161 SYR4 2012–2019
Dibromochloromethane
18.57 µg/L
No EPA limit set
worst single sample: 25.4 µg/L
123/161 SYR4 2012–2019
Copper
117.8 µg/L 9.1%
of the EPA limit 1300 µg/L
worst single sample: 251 µg/L
65/90 SYR4 2013–2019
Bromoform
11.615 µg/L
No EPA limit set
worst single sample: 21 µg/L
48/161 SYR4 2012–2019
Nitrate
834.5 µg/L 8.3%
of the EPA limit 10000 µg/L
worst single sample: 840 µg/L
32/32 SYR4 2012–2019
Dichloroacetic Acid
14.705 µg/L
No EPA limit set
worst single sample: 14.8 µg/L
20/20 SYR4 2018–2019
Trichloroacetic Acid
9.87 µg/L
No EPA limit set
worst single sample: 11.2 µg/L
20/20 SYR4 2018–2019
Lead
212.5 µg/L 1417%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 334 µg/L
16/90 SYR4 2013–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
13/13 LCR 2025
Dibromoacetic Acid
2.15 µg/L
No EPA limit set
worst single sample: 2.2 µg/L
3/20 SYR4 2018–2019
93 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAtrazineBhc-GammaBariumBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneFluorideGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
TONY NOKOVICH
Phone
570-538-4439

Frequently asked questions about Pa American White Deer

Is Pa American White Deer tap water safe to drink?

EPA monitoring detected 13 contaminants in Pa American White Deer's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Pa American White Deer's water?

EPA monitoring detected Bromodichloromethane, Chloroform, TTHM, Total Haloacetic Acids (HAA5), Dibromochloromethane, and others. The full list with the level and data source for each is above.

How many people does Pa American White Deer serve?

Pa American White Deer reports serving 30,209 people in Pennsylvania, per its EPA record.

Has Pa American White Deer had any water quality violations?

The EPA has 7 violations on file for Pa American White Deer, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.