← Pennsylvania

Tap water quality report

Locust Grove Retirement Home

EPA monitoring tested this supplier for 81 contaminants and detected 10. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

81
contaminants tested
10
detected
177
people served
9
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Juniata

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

9
health-based violations
163
violations on file
1
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2022-05-01 → 2022-05-31
TT Health-based Resolved 2022-05-01 → 2022-05-31
TT Health-based Resolved 2022-05-01 → 2022-05-31
TT Health-based Resolved 2019-06-01 → 2019-06-30
TT Health-based Resolved 2019-06-01 → 2019-06-30
TT Health-based Resolved 2014-08-01 → 2014-08-31
TT Health-based Resolved 2014-08-01 → 2014-08-31
TT Health-based Resolved 2014-08-01 → 2014-08-31
TT Health-based Resolved 2014-08-01 → 2014-08-31
MR Monitoring Archived 2026-02-01 → 2026-02-28

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
280 µg/L 22%
of the EPA limit 1300 µg/L
worst single sample: 1600 µg/L
56/56 SYR4 2013–2019
Lead
102 µg/L 680%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 140 µg/L
20/55 SYR4 2013–2019
Nitrate
2260 µg/L 23%
of the EPA limit 10000 µg/L
6/16 SYR4 2012–2019
Lead
0.1000 mg/L 667%
above the EPA limit of 0.0150 mg/L
5/5 LCR 2014
Dibromochloromethane
2.923 µg/L
No EPA limit set
worst single sample: 3.1 µg/L
4/4 SYR4 2012–2018
TTHM
13.485 µg/L 17%
of the EPA limit 80 µg/L
worst single sample: 13.8 µg/L
4/4 SYR4 2012–2018
Bromodichloromethane
5.334 µg/L
No EPA limit set
worst single sample: 5.54 µg/L
3/4 SYR4 2012–2018
Bromoform
2.573 µg/L
No EPA limit set
worst single sample: 2.77 µg/L
3/4 SYR4 2012–2018
Chloroform
4.288 µg/L
No EPA limit set
worst single sample: 4.37 µg/L
3/4 SYR4 2012–2018
Barium
48.62 µg/L 2.4%
of the EPA limit 2000 µg/L
worst single sample: 49.1 µg/L
2/3 SYR4 2012–2018
71 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,3,7,8-TCDD2,4,5-TP2,4-DAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDichloroacetic AcidDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneFluorideGlyphosateGross Beta Particle ActivityHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Haloacetic Acids (HAA5)Total Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MISSING NAME
Phone
717-436-8921

Frequently asked questions about Locust Grove Retirement Home

Is Locust Grove Retirement Home tap water safe to drink?

EPA monitoring detected 10 contaminants in Locust Grove Retirement Home's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Locust Grove Retirement Home's water?

EPA monitoring detected Copper, Lead, Nitrate, Lead, Dibromochloromethane, and others. The full list with the level and data source for each is above.

How many people does Locust Grove Retirement Home serve?

Locust Grove Retirement Home reports serving 177 people in Pennsylvania, per its EPA record.

Has Locust Grove Retirement Home had any water quality violations?

The EPA has 163 violations on file for Locust Grove Retirement Home, of which 9 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.