Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| TT | Health-based | Resolved | 2008-04-01 → 2008-04-30 |
| TT | Health-based | Resolved | 2008-04-01 → 2008-04-30 |
| TT | Health-based | Resolved | 2008-04-01 → 2008-04-30 |
| TT | Health-based | Resolved | 2008-04-01 → 2008-04-30 |
| TT | Health-based | Resolved | 2008-04-01 → 2008-04-30 |
| MCL | Health-based | Resolved | 2001-09-01 → 2001-09-30 |
| MCL | Health-based | Resolved | 2001-09-01 → 2001-09-30 |
| MCL | Health-based | Resolved | 2001-09-01 → 2001-09-30 |
| TT | Health-based | Resolved | 2001-05-01 → 2001-05-31 |
| TT | Health-based | Resolved | 2001-05-01 → 2001-05-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Chloroform | 86.365 µg/L No EPA limit set
worst single sample: 120 µg/L | 128/128 | SYR4 | 2012–2019 |
| TTHM | 95.01 µg/L 119% of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 127 µg/L | 128/128 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 62.025 µg/L 103% of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 130 µg/L | 128/128 | SYR4 | 2012–2019 |
| Bromodichloromethane | 8.011 µg/L No EPA limit set
worst single sample: 9.63 µg/L | 127/128 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 35.62 µg/L No EPA limit set
worst single sample: 64.4 µg/L | 99/100 | SYR4 | 2013–2019 |
| Dichloroacetic Acid | 36.48 µg/L No EPA limit set
worst single sample: 63.8 µg/L | 98/100 | SYR4 | 2013–2019 |
| Copper | 203.9 µg/L 16% of the EPA limit 1300 µg/L
worst single sample: 404 µg/L | 83/90 | SYR4 | 2013–2019 |
| Lead | 5.2585 µg/L 35% of the EPA limit 15 µg/L
worst single sample: 5.92 µg/L | 42/90 | SYR4 | 2013–2019 |
| Dibromochloromethane | 1.7785 µg/L No EPA limit set
worst single sample: 1.82 µg/L | 28/128 | SYR4 | 2012–2019 |
| Lead | 0.00097 mg/L 6.5% of the EPA limit 0.0150 mg/L | 13/13 | LCR | 2025 |
| Barium | 30.625 µg/L 1.5% of the EPA limit 2000 µg/L
worst single sample: 30.8 µg/L | 8/8 | SYR4 | 2012–2019 |
| Fluoride | 1036.3 µg/L 26% of the EPA limit 4000 µg/L
worst single sample: 1090 µg/L | 3/8 | SYR4 | 2012–2019 |
| Monochloroacetic Acid | 2.898 µg/L No EPA limit set
worst single sample: 2.93 µg/L | 3/100 | SYR4 | 2013–2019 |
| Nitrate | 513 µg/L 5.1% of the EPA limit 10000 µg/L | 2/16 | SYR4 | 2012–2019 |
96 contaminants tested, none detected
Utility contact
Frequently asked questions about Huntingdon Boro Water Dept
Is Huntingdon Boro Water Dept tap water safe to drink?
EPA monitoring detected 14 contaminants in Huntingdon Boro Water Dept's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Huntingdon Boro Water Dept's water?
EPA monitoring detected Chloroform, TTHM, Total Haloacetic Acids (HAA5), Bromodichloromethane, Trichloroacetic Acid, and others. The full list with the level and data source for each is above.
How many people does Huntingdon Boro Water Dept serve?
Huntingdon Boro Water Dept reports serving 13,776 people in Pennsylvania, per its EPA record.
Has Huntingdon Boro Water Dept had any water quality violations?
The EPA has 195 violations on file for Huntingdon Boro Water Dept, of which 23 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.