← Pennsylvania

Tap water quality report

Hastings Muni Auth

EPA monitoring tested this supplier for 111 contaminants and detected 18. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

111
contaminants tested
18
detected
2,100
people served
0
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Cambria

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
122
violations on file
2
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2026-01-01 → 2026-03-31
MR Monitoring Resolved 2026-01-01 → 2026-03-31
MR Monitoring Resolved 2026-01-01 → 2026-03-31
MR Monitoring Resolved 2026-01-01 → 2026-03-31
MR Monitoring Resolved 2026-01-01 → 2026-03-31
MR Monitoring Resolved 2026-01-01 → 2026-03-31
MR Monitoring Resolved 2026-01-01 → 2026-03-31
MR Monitoring Resolved 2026-01-01 → 2026-03-31
MR Monitoring Resolved 2025-07-01 → 2025-09-30
MR Monitoring Resolved 2025-07-01 → 2025-09-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
779.8 µg/L 60%
of the EPA limit 1300 µg/L
worst single sample: 1160 µg/L
42/43 SYR4 2013–2019
Bromodichloromethane
7.91 µg/L
No EPA limit set
worst single sample: 10 µg/L
31/31 SYR4 2012–2019
Chloroform
11.25 µg/L
No EPA limit set
worst single sample: 20 µg/L
31/31 SYR4 2012–2019
TTHM
26.24 µg/L 33%
of the EPA limit 80 µg/L
worst single sample: 30 µg/L
31/31 SYR4 2012–2019
Dibromochloromethane
8.5685 µg/L
No EPA limit set
worst single sample: 10.37 µg/L
30/31 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
14.95 µg/L 25%
of the EPA limit 60 µg/L
worst single sample: 83.5 µg/L
26/33 SYR4 2012–2019
Bromoform
4.639 µg/L
No EPA limit set
worst single sample: 4.76 µg/L
12/31 SYR4 2012–2019
Nitrate
1790 µg/L 18%
of the EPA limit 10000 µg/L
8/14 SYR4 2012–2019
Barium
34 µg/L 1.7%
of the EPA limit 2000 µg/L
worst single sample: 37 µg/L
7/8 SYR4 2012–2019
Dichloroacetic Acid
2.7975 µg/L
No EPA limit set
worst single sample: 3.01 µg/L
6/6 SYR4 2015–2019
Fluoride
164.6 µg/L 4.1%
of the EPA limit 4000 µg/L
worst single sample: 171 µg/L
5/8 SYR4 2012–2019
Selenium
7.22 µg/L 14%
of the EPA limit 50 µg/L
worst single sample: 7.3 µg/L
5/9 SYR4 2012–2019
Lithium
18.5 µg/L
No EPA limit set
5/6 UCMR-5 2025
Trichloroacetic Acid
2.738 µg/L
No EPA limit set
worst single sample: 2.82 µg/L
3/6 SYR4 2015–2019
Lead
0.0020 mg/L 13%
of the EPA limit 0.0150 mg/L
2/2 LCR 1995
Bromate
23 µg/L 230%
of the EPA limit, at the 95th percentile of samples — 10 µg/L
1/1 SYR4 2017
Chromium
0.9000 µg/L 0.9%
of the EPA limit 100 µg/L
1/8 SYR4 2012–2019
Lead
2.8 µg/L 19%
of the EPA limit 15 µg/L
1/32 SYR4 2013–2019
93 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,3,7,8-TCDD2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
THOMAS KINNEY
Phone
814-247-6663

Frequently asked questions about Hastings Muni Auth

Is Hastings Muni Auth tap water safe to drink?

EPA monitoring detected 18 contaminants in Hastings Muni Auth's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Hastings Muni Auth's water?

EPA monitoring detected Copper, Bromodichloromethane, Chloroform, TTHM, Dibromochloromethane, and others. The full list with the level and data source for each is above.

How many people does Hastings Muni Auth serve?

Hastings Muni Auth reports serving 2,100 people in Pennsylvania, per its EPA record.

Has Hastings Muni Auth had any water quality violations?

The EPA has 122 violations on file for Hastings Muni Auth, of which 0 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.