Scma-Tremont

EPA monitoring tested this supplier for 80 contaminants and detected 14. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

80
contaminants tested
14
detected
2,515
people served
10
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Schuylkill

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

10
health-based violations
164
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 1992-01-01 → 1997-02-04
TT Health-based Resolved 1992-01-01 → 1997-02-04
TT Health-based Resolved 1992-01-01 → 1997-02-04
MCL Health-based Resolved 1990-01-30 → 1990-02-28
MCL Health-based Resolved 1990-01-30 → 1990-02-28
MCL Health-based Resolved 1990-01-30 → 1990-02-28
MCL Health-based Archived 1984-05-16 → 1984-07-15
MCL Health-based Archived 1984-05-16 → 1984-07-15
MCL Health-based Archived 1984-05-16 → 1984-07-15
MCL Health-based Archived 1984-05-16 → 1984-07-15

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
615.2 µg/L 47%
of the EPA limit 1300 µg/L
worst single sample: 725 µg/L
30/30 SYR4 2013–2019
Chloroform
17.67 µg/L
No EPA limit set
worst single sample: 18 µg/L
12/12 SYR4 2012–2019
Lead
24.25 µg/L 162%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 29.2 µg/L
11/30 SYR4 2013–2019
Bromodichloromethane
5.521 µg/L
No EPA limit set
worst single sample: 5.62 µg/L
10/11 SYR4 2012–2019
TTHM
24.715 µg/L 31%
of the EPA limit 80 µg/L
worst single sample: 25.1 µg/L
8/8 SYR4 2012–2019
Dibromochloromethane
1.889 µg/L
No EPA limit set
worst single sample: 1.97 µg/L
7/9 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
7.1425 µg/L 12%
of the EPA limit 60 µg/L
worst single sample: 7.21 µg/L
6/8 SYR4 2012–2019
Dichloroacetic Acid
5 µg/L
No EPA limit set
3/3 SYR4 2017–2019
Trichloroacetic Acid
2.9 µg/L
No EPA limit set
worst single sample: 3 µg/L
3/3 SYR4 2017–2019
Barium
61.83 µg/L 3.1%
of the EPA limit 2000 µg/L
worst single sample: 62.6 µg/L
2/3 SYR4 2012–2018
Combined Uranium
0.2596 µg/L 0.9%
of the EPA limit 30 µg/L
1/1 SYR4 2012
Lead
0.0400 mg/L 267%
above the EPA limit of 0.0150 mg/L
1/1 LCR 1995
Mercury
0.0490 µg/L 2.5%
of the EPA limit 2 µg/L
1/3 SYR4 2012–2018
Selenium
0.2200 µg/L 0.4%
of the EPA limit 50 µg/L
1/3 SYR4 2012–2018
66 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,3,7,8-TCDD2,4,5-TP2,4-DAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneFluorideGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitrateNitriteOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
PATRICK CAULFIELD
Phone
570-622-8240

Frequently asked questions about Scma-Tremont

Is Scma-Tremont tap water safe to drink?

EPA monitoring detected 14 contaminants in Scma-Tremont's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Scma-Tremont's water?

EPA monitoring detected Copper, Chloroform, Lead, Bromodichloromethane, TTHM, and others. The full list with the level and data source for each is above.

How many people does Scma-Tremont serve?

Scma-Tremont reports serving 2,515 people in Pennsylvania, per its EPA record.

Has Scma-Tremont had any water quality violations?

The EPA has 164 violations on file for Scma-Tremont, of which 10 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.