Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| RPT | Monitoring | Resolved | 2018-02-01 |
| RPT | Monitoring | Resolved | 2018-02-01 |
| MR | Monitoring | Resolved | 2018-01-01 → 2018-03-31 |
| MR | Monitoring | Resolved | 2018-01-01 → 2018-03-31 |
| MR | Monitoring | Resolved | 2016-10-01 |
| MR | Monitoring | Resolved | 2016-10-01 |
| MR | Monitoring | Resolved | 2016-10-01 |
| MR | Monitoring | Resolved | 2016-10-01 |
| MR | Monitoring | Resolved | 2014-07-01 → 2014-07-31 |
| MR | Monitoring | Resolved | 2014-07-01 → 2014-07-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 392.95 µg/L 30% of the EPA limit 1300 µg/L
worst single sample: 514 µg/L | 30/30 | SYR4 | 2013–2019 |
| Lead | 28.7 µg/L 191% of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 69 µg/L | 14/30 | SYR4 | 2013–2019 |
| Bromodichloromethane | 3.46 µg/L No EPA limit set
worst single sample: 3.6 µg/L | 8/8 | SYR4 | 2013–2019 |
| Chloroform | 2.82 µg/L No EPA limit set
worst single sample: 3.1 µg/L | 8/8 | SYR4 | 2013–2019 |
| Dibromochloromethane | 5.175 µg/L No EPA limit set
worst single sample: 5.7 µg/L | 8/8 | SYR4 | 2013–2019 |
| TTHM | 14.77 µg/L 18% of the EPA limit 80 µg/L
worst single sample: 16.1 µg/L | 8/8 | SYR4 | 2013–2019 |
| Total Haloacetic Acids (HAA5) | 3.7815 µg/L 6.3% of the EPA limit 60 µg/L
worst single sample: 3.96 µg/L | 8/8 | SYR4 | 2013–2019 |
| Bromoform | 4.44 µg/L No EPA limit set
worst single sample: 5.4 µg/L | 7/8 | SYR4 | 2013–2019 |
| Lead | 0.0190 mg/L 127% above the EPA limit of 0.0150 mg/L | 4/4 | LCR | 1996 |
| Dichloroacetic Acid | 3.7 µg/L No EPA limit set
worst single sample: 4 µg/L | 3/3 | SYR4 | 2017–2019 |
| Dibromoacetic Acid | 2 µg/L No EPA limit set | 2/3 | SYR4 | 2017–2019 |
3 contaminants tested, none detected
Utility contact
Frequently asked questions about Beth 512
Is Beth 512 tap water safe to drink?
EPA monitoring detected 11 contaminants in Beth 512's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Beth 512's water?
EPA monitoring detected Copper, Lead, Bromodichloromethane, Chloroform, Dibromochloromethane, and others. The full list with the level and data source for each is above.
How many people does Beth 512 serve?
Beth 512 reports serving 725 people in Pennsylvania, per its EPA record.
Has Beth 512 had any water quality violations?
The EPA has 24 violations on file for Beth 512, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.