← Pennsylvania

Tap water quality report

Northridge at Camelback

EPA monitoring tested this supplier for 76 contaminants and detected 17. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

76
contaminants tested
17
detected
330
people served
8
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Monroe

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

8
health-based violations
480
violations on file
2
still open
ViolationTypeStatusPeriod
TT Health-based Unaddressed 2025-04-01
TT Health-based Resolved 2020-02-01 → 2020-02-29
TT Health-based Resolved 2020-02-01 → 2020-02-29
TT Health-based Resolved 2020-02-01 → 2020-02-29
MCL Health-based Resolved 2009-11-01 → 2009-11-30
MCL Health-based Resolved 2009-11-01 → 2009-11-30
MCL Health-based Resolved 2009-11-01 → 2009-11-30
MCL Health-based Resolved 2009-11-01 → 2009-11-30
MR Monitoring Resolved 2025-09-01 → 2025-09-30
MR Monitoring Resolved 2025-09-01 → 2025-09-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
973.5 µg/L 9.7%
of the EPA limit 10000 µg/L
worst single sample: 1000 µg/L
22/36 SYR4 2012–2019
Copper
153.3 µg/L 12%
of the EPA limit 1300 µg/L
worst single sample: 161 µg/L
15/15 SYR4 2013–2019
Lead
4.028 µg/L 27%
of the EPA limit 15 µg/L
worst single sample: 4.6 µg/L
12/15 SYR4 2013–2019
Arsenic
6.95 µg/L 70%
of the EPA limit 10 µg/L
worst single sample: 7 µg/L
6/6 SYR4 2012–2018
Barium
82.725 µg/L 4.1%
of the EPA limit 2000 µg/L
worst single sample: 87.6 µg/L
6/6 SYR4 2012–2018
Bromodichloromethane
1.34 µg/L
No EPA limit set
worst single sample: 1.4 µg/L
5/5 SYR4 2013–2018
Dibromochloromethane
1 µg/L
No EPA limit set
5/5 SYR4 2013–2018
Lead
0.1228 mg/L 819%
above the EPA limit of 0.0150 mg/L
5/5 LCR 2022
TTHM
4.52 µg/L 5.6%
of the EPA limit 80 µg/L
worst single sample: 4.8 µg/L
5/5 SYR4 2013–2018
Chloroform
2.175 µg/L
No EPA limit set
worst single sample: 2.4 µg/L
4/5 SYR4 2013–2018
Total Haloacetic Acids (HAA5)
5.1 µg/L 8.5%
of the EPA limit 60 µg/L
worst single sample: 5.5 µg/L
3/5 SYR4 2013–2018
Combined Uranium
1.57129 µg/L 5.2%
of the EPA limit 30 µg/L
worst single sample: 1.6539 µg/L
2/3 SYR4 2013–2019
Antimony, Total
0.6000 µg/L 10%
of the EPA limit 6 µg/L
1/6 SYR4 2012–2018
Bromoform
0.6000 µg/L
No EPA limit set
1/5 SYR4 2013–2018
Di(2-ethylhexyl) Adipate
0.9000 µg/L 0.2%
of the EPA limit 400 µg/L
1/17 SYR4 2012–2019
Di(2-ethylhexyl) Phthalate
0.7000 µg/L 12%
of the EPA limit 6 µg/L
1/17 SYR4 2012–2019
Toluene
0.8200 µg/L 0.1%
of the EPA limit 1000 µg/L
1/23 SYR4 2012–2019
59 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,3,7,8-TCDD2,4,5-TP2,4-DAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneFluorideGlyphosateGross Beta Particle ActivityHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
GINNY FISH
Phone
570-629-5570

Frequently asked questions about Northridge at Camelback

Is Northridge at Camelback tap water safe to drink?

EPA monitoring detected 17 contaminants in Northridge at Camelback's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Northridge at Camelback's water?

EPA monitoring detected Nitrate, Copper, Lead, Arsenic, Barium, and others. The full list with the level and data source for each is above.

How many people does Northridge at Camelback serve?

Northridge at Camelback reports serving 330 people in Pennsylvania, per its EPA record.

Has Northridge at Camelback had any water quality violations?

The EPA has 480 violations on file for Northridge at Camelback, of which 8 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.