← Pennsylvania

Tap water quality report

Aqua Pa Fieldcrest

EPA monitoring tested this supplier for 79 contaminants and detected 17. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

79
contaminants tested
17
detected
112
people served
0
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Luzerne

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
127
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2023-10-01 → 2023-12-31
MR Monitoring Resolved 2023-10-01 → 2023-12-31
MR Monitoring Resolved 2023-10-01 → 2023-12-31
MR Monitoring Resolved 2023-10-01 → 2023-12-31
MR Monitoring Resolved 2023-10-01 → 2023-12-31
MR Monitoring Resolved 2023-10-01 → 2023-12-31
MR Monitoring Resolved 2015-07-01 → 2015-09-30
MR Monitoring Resolved 2015-07-01 → 2015-09-30
MR Monitoring Resolved 2015-07-01 → 2015-09-30
MR Monitoring Resolved 2015-07-01 → 2015-09-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
507 µg/L 39%
of the EPA limit 1300 µg/L
worst single sample: 640 µg/L
15/15 SYR4 2013–2019
TTHM
94.5 µg/L 118%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 101.9 µg/L
6/6 SYR4 2012–2019
Chloroform
1.9 µg/L
No EPA limit set
5/5 SYR4 2018–2019
Total Haloacetic Acids (HAA5)
15.24 µg/L 25%
of the EPA limit 60 µg/L
worst single sample: 15.7 µg/L
5/6 SYR4 2012–2019
Lead
0.2290 mg/L 1527%
above the EPA limit of 0.0150 mg/L
4/4 LCR 1998
Arsenic
2.86 µg/L 29%
of the EPA limit 10 µg/L
worst single sample: 2.9 µg/L
3/3 SYR4 2012–2018
Barium
487.4 µg/L 24%
of the EPA limit 2000 µg/L
worst single sample: 501 µg/L
3/3 SYR4 2012–2018
Bromodichloromethane
7.42 µg/L
No EPA limit set
worst single sample: 7.6 µg/L
3/3 SYR4 2018–2019
Bromoform
66.07 µg/L
No EPA limit set
worst single sample: 69 µg/L
3/3 SYR4 2018–2019
Dibromochloromethane
25.64 µg/L
No EPA limit set
worst single sample: 26 µg/L
3/3 SYR4 2018–2019
Fluoride
164 µg/L 4.1%
of the EPA limit 4000 µg/L
worst single sample: 170 µg/L
3/3 SYR4 2012–2018
Chromium
2.095 µg/L 2.1%
of the EPA limit 100 µg/L
worst single sample: 2.1 µg/L
2/3 SYR4 2012–2018
Dibromoacetic Acid
13.185 µg/L
No EPA limit set
worst single sample: 13.4 µg/L
2/3 SYR4 2018–2019
Lead
6.805 µg/L 45%
of the EPA limit 15 µg/L
worst single sample: 6.9 µg/L
2/15 SYR4 2013–2019
Monobromoacetic Acid
2.265 µg/L
No EPA limit set
worst single sample: 2.3 µg/L
2/3 SYR4 2018–2019
Di(2-ethylhexyl) Phthalate
3.26 µg/L 54%
of the EPA limit 6 µg/L
1/13 SYR4 2012–2019
Dichloroacetic Acid
1.1 µg/L
No EPA limit set
1/3 SYR4 2018–2019
62 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,3,7,8-TCDD2,4,5-TP2,4-DAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonochloroacetic AcidNitrateNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
DAVID HOOGSTAD
Phone
570-443-7099

Frequently asked questions about Aqua Pa Fieldcrest

Is Aqua Pa Fieldcrest tap water safe to drink?

EPA monitoring detected 17 contaminants in Aqua Pa Fieldcrest's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Aqua Pa Fieldcrest's water?

EPA monitoring detected Copper, TTHM, Chloroform, Total Haloacetic Acids (HAA5), Lead, and others. The full list with the level and data source for each is above.

How many people does Aqua Pa Fieldcrest serve?

Aqua Pa Fieldcrest reports serving 112 people in Pennsylvania, per its EPA record.

Has Aqua Pa Fieldcrest had any water quality violations?

The EPA has 127 violations on file for Aqua Pa Fieldcrest, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.