← Pennsylvania

Tap water quality report

North Wales Water Authority

EPA monitoring tested this supplier for 111 contaminants and detected 32. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

111
contaminants tested
32
detected
72,496
people served
0
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Montgomery

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
430
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Archived 2025-04-01 → 2025-06-30
MR Monitoring Archived 2025-04-01 → 2025-06-30
MR Monitoring Resolved 2025-03-01 → 2025-03-31
MR Monitoring Resolved 2025-03-01 → 2025-03-31
MR Monitoring Resolved 2022-07-01 → 2022-07-31
MR Monitoring Resolved 2022-07-01 → 2022-07-31
MR Monitoring Resolved 2022-04-01 → 2022-04-30
MR Monitoring Resolved 2022-04-01 → 2022-04-30
MR Monitoring Resolved 2021-09-01 → 2021-09-30
MR Monitoring Resolved 2021-09-01 → 2021-09-30

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
PFBS 0.0064 µg/L 12/16 2025
PFOA 0.0130 µg/L 12/16 2025
PFOS 0.0111 µg/L 11/16 2025
Pfhxa 0.0081 µg/L 10/16 2025
Pfpea 0.0093 µg/L 10/16 2025
Pfhpa 0.0058 µg/L 7/16 2025
Pfba 0.0068 µg/L 3/16 2025
PFHXS 0.0037 µg/L 2/16 2025
PFNA 0.0056 µg/L 1/16 2025

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
3995 µg/L 40%
of the EPA limit 10000 µg/L
worst single sample: 4360 µg/L
516/558 SYR4 2012–2019
Chloroform
38.31 µg/L
No EPA limit set
worst single sample: 55.4 µg/L
379/379 SYR4 2012–2019
TTHM
56.14 µg/L 70%
of the EPA limit 80 µg/L
worst single sample: 76.4 µg/L
303/303 SYR4 2012–2019
Bromodichloromethane
11.63 µg/L
No EPA limit set
worst single sample: 15.3 µg/L
295/295 SYR4 2012–2019
Dibromochloromethane
5.334 µg/L
No EPA limit set
worst single sample: 9.05 µg/L
294/294 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
21.145 µg/L 35%
of the EPA limit 60 µg/L
worst single sample: 40.5 µg/L
272/277 SYR4 2012–2019
Copper
537.225 µg/L 41%
of the EPA limit 1300 µg/L
worst single sample: 1200 µg/L
152/152 SYR4 2013–2019
Bromate
3.445 µg/L 34%
of the EPA limit 10 µg/L
worst single sample: 3.8 µg/L
92/92 SYR4 2012–2019
Bromoform
1.5875 µg/L
No EPA limit set
worst single sample: 2.8 µg/L
70/271 SYR4 2012–2019
Lead
8.9 µg/L 59%
of the EPA limit 15 µg/L
worst single sample: 10.6 µg/L
42/152 SYR4 2013–2019
Dichloroacetic Acid
23.4 µg/L
No EPA limit set
worst single sample: 28.1 µg/L
41/41 SYR4 2018–2019
Trichloroacetic Acid
12.4 µg/L
No EPA limit set
worst single sample: 12.5 µg/L
41/41 SYR4 2018–2019
Barium
450.2 µg/L 23%
of the EPA limit 2000 µg/L
worst single sample: 508 µg/L
33/35 SYR4 2012–2019
Lead
0.0016 mg/L 11%
of the EPA limit 0.0150 mg/L
12/12 LCR 2025
Combined Uranium
13.7408 µg/L 46%
of the EPA limit 30 µg/L
worst single sample: 14.0805 µg/L
9/13 SYR4 2014–2017
Arsenic
4.3 µg/L 43%
of the EPA limit 10 µg/L
worst single sample: 5 µg/L
8/35 SYR4 2012–2019
Chromium
2 µg/L 2%
of the EPA limit 100 µg/L
8/35 SYR4 2012–2019
Dibromoacetic Acid
1.3885 µg/L
No EPA limit set
worst single sample: 1.45 µg/L
4/41 SYR4 2018–2019
Atrazine
0.2950 µg/L 9.8%
of the EPA limit 3 µg/L
worst single sample: 0.3000 µg/L
2/56 SYR4 2012–2019
Cyanide
10 µg/L 5%
of the EPA limit 200 µg/L
2/35 SYR4 2012–2019
Lithium
9.65 µg/L
No EPA limit set
2/16 UCMR-5 2025
Antimony, Total
0.7000 µg/L 12%
of the EPA limit 6 µg/L
1/35 SYR4 2012–2019
Di(2-ethylhexyl) Phthalate
1.8 µg/L 30%
of the EPA limit 6 µg/L
1/53 SYR4 2012–2019
79 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,3,7,8-TCDD2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAsbestosBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneFluorideGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNetfosaaNfdhaNmefosaaNitriteOxamylPfdaPfdoaPfeesaPfhpsPfmbaPfmpaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
JOSEPH MURPHY
Phone
215-699-4836

Frequently asked questions about North Wales Water Authority

Is North Wales Water Authority tap water safe to drink?

EPA monitoring detected 32 contaminants in North Wales Water Authority's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in North Wales Water Authority's water?

EPA monitoring detected Nitrate, Chloroform, TTHM, Bromodichloromethane, Dibromochloromethane, and others. The full list with the level and data source for each is above.

How many people does North Wales Water Authority serve?

North Wales Water Authority reports serving 72,496 people in Pennsylvania, per its EPA record.

Has North Wales Water Authority had any water quality violations?

The EPA has 430 violations on file for North Wales Water Authority, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.