Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MR | Monitoring | Resolved | 2011-07-01 → 2011-09-30 |
| MR | Monitoring | Resolved | 2011-07-01 → 2011-09-30 |
| MR | Monitoring | Resolved | 2011-07-01 → 2011-09-30 |
| MR | Monitoring | Resolved | 2011-07-01 → 2011-09-30 |
PFAS detected
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Total Haloacetic Acids (HAA5) | 59.93 µg/L 100% of the EPA limit 60 µg/L
worst single sample: 102 µg/L | 755/756 | SYR4 | 2012–2019 |
| Copper | 312.5 µg/L 24% of the EPA limit 1300 µg/L
worst single sample: 1400 µg/L | 256/258 | SYR4 | 2012–2019 |
| Bromodichloromethane | 11.845 µg/L No EPA limit set
worst single sample: 17 µg/L | 252/252 | SYR4 | 2012–2019 |
| Chloroform | 68.435 µg/L No EPA limit set
worst single sample: 84.4 µg/L | 252/252 | SYR4 | 2012–2019 |
| TTHM | 75.9 µg/L 95% of the EPA limit 80 µg/L
worst single sample: 92.5 µg/L | 252/252 | SYR4 | 2012–2019 |
| Nitrate | 8390 µg/L 84% of the EPA limit 10000 µg/L
worst single sample: 9030 µg/L | 130/130 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 31.425 µg/L No EPA limit set
worst single sample: 33 µg/L | 128/128 | SYR4 | 2018–2019 |
| Trichloroacetic Acid | 27.06 µg/L No EPA limit set
worst single sample: 30 µg/L | 128/128 | SYR4 | 2018–2019 |
| Lead | 30.9 µg/L 206% of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 81 µg/L | 127/258 | SYR4 | 2012–2019 |
| Dibromochloromethane | 2.9 µg/L No EPA limit set
worst single sample: 3.1 µg/L | 97/252 | SYR4 | 2012–2019 |
| Monochloroacetic Acid | 4.29 µg/L No EPA limit set
worst single sample: 4.8 µg/L | 63/128 | SYR4 | 2018–2019 |
| Lead | 0.0048 mg/L 32% of the EPA limit 0.0150 mg/L | 28/28 | LCR | 2025 |
| Barium | 30.65 µg/L 1.5% of the EPA limit 2000 µg/L
worst single sample: 31 µg/L | 8/8 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 1.265 µg/L No EPA limit set
worst single sample: 1.3 µg/L | 8/128 | SYR4 | 2018–2019 |
| Fluoride | 772.35 µg/L 19% of the EPA limit 4000 µg/L
worst single sample: 779 µg/L | 8/8 | SYR4 | 2012–2019 |
| Atrazine | 0.6760 µg/L 23% of the EPA limit 3 µg/L
worst single sample: 0.7300 µg/L | 5/14 | SYR4 | 2012–2019 |
| Monobromoacetic Acid | 2.54 µg/L No EPA limit set
worst single sample: 2.6 µg/L | 4/128 | SYR4 | 2018–2019 |
| 2,4-D | 0.1800 µg/L 0.3% of the EPA limit 70 µg/L | 1/17 | SYR4 | 2012–2019 |
89 contaminants tested, none detected
Utility contact
Frequently asked questions about Chester Water Authority
Is Chester Water Authority tap water safe to drink?
EPA monitoring detected 22 contaminants in Chester Water Authority's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Chester Water Authority's water?
EPA monitoring detected Total Haloacetic Acids (HAA5), Copper, Bromodichloromethane, Chloroform, TTHM, and others. The full list with the level and data source for each is above.
How many people does Chester Water Authority serve?
Chester Water Authority reports serving 140,437 people in Pennsylvania, per its EPA record.
Has Chester Water Authority had any water quality violations?
The EPA has 4 violations on file for Chester Water Authority, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.