← Pennsylvania

Tap water quality report

Village 2 Community Assoc

EPA monitoring tested this supplier for 80 contaminants and detected 18. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

80
contaminants tested
18
detected
650
people served
0
health-based violations
Water source
Ground water
Ownership
Mixed public/private
Counties served
Bucks

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
496
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Archived 2025-07-01 → 2025-09-30
MR Monitoring Archived 2025-07-01 → 2025-09-30
MR Monitoring Resolved 2022-10-01
MR Monitoring Resolved 2022-10-01
MON Monitoring Resolved 2021-08-01 → 2021-08-31
MON Monitoring Resolved 2021-08-01 → 2021-08-31
MON Monitoring Resolved 2021-08-01 → 2021-08-31
MON Monitoring Resolved 2021-08-01 → 2021-08-31
MON Monitoring Resolved 2021-08-01 → 2021-08-31
MR Monitoring Resolved 2019-07-01 → 2019-09-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
258.05 µg/L 20%
of the EPA limit 1300 µg/L
worst single sample: 295 µg/L
30/30 SYR4 2013–2019
Lead
3.11 µg/L 21%
of the EPA limit 15 µg/L
worst single sample: 4.7 µg/L
24/30 SYR4 2013–2019
Nitrate
2800 µg/L 28%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Dibromochloromethane
4.9285 µg/L
No EPA limit set
worst single sample: 5.39 µg/L
14/14 SYR4 2012–2019
Bromoform
4.5945 µg/L
No EPA limit set
worst single sample: 5.81 µg/L
12/12 SYR4 2012–2019
Arsenic
8.25 µg/L 83%
of the EPA limit 10 µg/L
worst single sample: 8.6 µg/L
11/11 SYR4 2012–2019
Chloroform
2.0145 µg/L
No EPA limit set
worst single sample: 2.1 µg/L
10/11 SYR4 2012–2019
TTHM
15.4 µg/L 19%
of the EPA limit 80 µg/L
worst single sample: 16.2 µg/L
6/6 SYR4 2012–2019
Bromodichloromethane
3.168 µg/L
No EPA limit set
worst single sample: 3.2 µg/L
5/6 SYR4 2012–2019
Barium
242.5 µg/L 12%
of the EPA limit 2000 µg/L
worst single sample: 244 µg/L
3/3 SYR4 2012–2018
Combined Uranium
8.15075 µg/L 27%
of the EPA limit 30 µg/L
worst single sample: 8.18606 µg/L
2/2 SYR4 2013–2019
Lead
0.0020 mg/L 13%
of the EPA limit 0.0150 mg/L
2/2 LCR 1996
Selenium
3.905 µg/L 7.8%
of the EPA limit 50 µg/L
worst single sample: 4 µg/L
2/3 SYR4 2012–2018
Antimony, Total
0.1200 µg/L 2%
of the EPA limit 6 µg/L
1/3 SYR4 2012–2018
Chromium
1.4 µg/L 1.4%
of the EPA limit 100 µg/L
1/3 SYR4 2012–2018
Dibromoacetic Acid
1.5 µg/L
No EPA limit set
1/2 SYR4 2018–2019
Mercury
0.0770 µg/L 3.9%
of the EPA limit 2 µg/L
1/3 SYR4 2012–2018
Total Haloacetic Acids (HAA5)
1.81 µg/L 3%
of the EPA limit 60 µg/L
1/7 SYR4 2012–2019
62 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,3,7,8-TCDD2,4,5-TP2,4-DAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDichloroacetic AcidDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneFluorideGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
DANIEL PEEL
Phone
215-862-2951

Frequently asked questions about Village 2 Community Assoc

Is Village 2 Community Assoc tap water safe to drink?

EPA monitoring detected 18 contaminants in Village 2 Community Assoc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Village 2 Community Assoc's water?

EPA monitoring detected Copper, Lead, Nitrate, Dibromochloromethane, Bromoform, and others. The full list with the level and data source for each is above.

How many people does Village 2 Community Assoc serve?

Village 2 Community Assoc reports serving 650 people in Pennsylvania, per its EPA record.

Has Village 2 Community Assoc had any water quality violations?

The EPA has 496 violations on file for Village 2 Community Assoc, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.