Tap water quality report

Solebury School

EPA monitoring tested this supplier for 79 contaminants and detected 17. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

79
contaminants tested
17
detected
300
people served
4
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Bucks

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

4
health-based violations
59
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2011-12-01 → 2011-12-31
MCL Health-based Resolved 2011-12-01 → 2011-12-31
MCL Health-based Resolved 2011-12-01 → 2011-12-31
MCL Health-based Resolved 2011-12-01 → 2011-12-31
MR Monitoring Resolved 2025-10-01 → 2025-10-31
MR Monitoring Resolved 2025-10-01 → 2025-10-31
MR Monitoring Resolved 2025-04-01 → 2025-04-30
MR Monitoring Resolved 2025-04-01 → 2025-04-30
MR Monitoring Resolved 2024-12-01 → 2024-12-31
MR Monitoring Resolved 2024-12-01 → 2024-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
2837.5 µg/L 28%
of the EPA limit 10000 µg/L
worst single sample: 2890 µg/L
36/36 SYR4 2012–2019
Copper
95.2 µg/L 7.3%
of the EPA limit 1300 µg/L
worst single sample: 164 µg/L
25/25 SYR4 2013–2019
Chloroform
2.42 µg/L
No EPA limit set
worst single sample: 2.7 µg/L
8/11 SYR4 2012–2018
Lead
15.265 µg/L 102%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 17.4 µg/L
8/25 SYR4 2013–2019
Bromodichloromethane
1.67 µg/L
No EPA limit set
worst single sample: 1.7 µg/L
7/11 SYR4 2012–2018
TTHM
5.139 µg/L 6.4%
of the EPA limit 80 µg/L
worst single sample: 5.4 µg/L
7/10 SYR4 2012–2018
Barium
90.975 µg/L 4.5%
of the EPA limit 2000 µg/L
worst single sample: 94.8 µg/L
6/8 SYR4 2012–2018
Dibromochloromethane
1.275 µg/L
No EPA limit set
worst single sample: 1.3 µg/L
6/10 SYR4 2012–2018
Chromium
2.085 µg/L 2.1%
of the EPA limit 100 µg/L
worst single sample: 2.1 µg/L
4/6 SYR4 2012–2018
Di(2-ethylhexyl) Phthalate
0.1066 µg/L 1.8%
of the EPA limit 6 µg/L
worst single sample: 0.1070 µg/L
4/12 SYR4 2012–2018
Di(2-ethylhexyl) Adipate
0.0555 µg/L 0%
of the EPA limit 400 µg/L
worst single sample: 0.0570 µg/L
3/12 SYR4 2012–2018
Arsenic
0.4175 µg/L 4.2%
of the EPA limit 10 µg/L
worst single sample: 0.4200 µg/L
2/6 SYR4 2012–2018
Combined Uranium
0.2263 µg/L 0.8%
of the EPA limit 30 µg/L
worst single sample: 0.2265 µg/L
2/8 SYR4 2014–2018
Selenium
1.295 µg/L 2.6%
of the EPA limit 50 µg/L
worst single sample: 1.3 µg/L
2/6 SYR4 2012–2018
Dichloroacetic Acid
1 µg/L
No EPA limit set
1/2 SYR4 2018
Mercury
0.0290 µg/L 1.5%
of the EPA limit 2 µg/L
1/6 SYR4 2012–2018
Total Haloacetic Acids (HAA5)
1.18 µg/L 2%
of the EPA limit 60 µg/L
1/10 SYR4 2012–2018
62 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,3,7,8-TCDD2,4,5-TP2,4-DAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDibromoacetic AcidDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneFluorideGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
TOM WILSCHUTZ
Phone
215-862-5261

Frequently asked questions about Solebury School

Is Solebury School tap water safe to drink?

EPA monitoring detected 17 contaminants in Solebury School's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Solebury School's water?

EPA monitoring detected Nitrate, Copper, Chloroform, Lead, Bromodichloromethane, and others. The full list with the level and data source for each is above.

How many people does Solebury School serve?

Solebury School reports serving 300 people in Pennsylvania, per its EPA record.

Has Solebury School had any water quality violations?

The EPA has 59 violations on file for Solebury School, of which 4 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.