← Oregon

Tap water quality report

Clayton Creek Mh Estates

EPA monitoring tested this supplier for 72 contaminants and detected 9. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

72
contaminants tested
9
detected
165
people served
1
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Jackson

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

1
health-based violations
27
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2001-12-01 → 2001-12-31
Other Monitoring Resolved 2023-07-01
MR Monitoring Archived 2023-01-01 → 2025-12-31
MR Monitoring Archived 2023-01-01 → 2025-12-31
MR Monitoring Archived 2023-01-01 → 2025-12-31
MR Monitoring Archived 2023-01-01 → 2025-12-31
MR Monitoring Archived 2023-01-01 → 2025-12-31
Other Monitoring Resolved 2004-10-19
Other Monitoring Resolved 2004-07-01
Other Monitoring Resolved 2003-10-19

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
102.04 µg/L 7.8%
of the EPA limit 1300 µg/L
worst single sample: 129 µg/L
17/17 SYR4 2012–2018
Lead
13 µg/L 87%
of the EPA limit 15 µg/L
worst single sample: 15.1 µg/L
16/17 SYR4 2012–2018
Lead
0.0054 mg/L 36%
of the EPA limit 0.0150 mg/L
15/15 LCR 2024
Combined Radium (-226 And -228)
0.8850 pCi/L 18%
of the EPA limit 5 pCi/L
worst single sample: 0.8900 pCi/L
3/3 SYR4 2012–2019
TTHM
44.35 µg/L 55%
of the EPA limit 80 µg/L
worst single sample: 46.3 µg/L
3/3 SYR4 2014–2019
Barium
45.9 µg/L 2.3%
of the EPA limit 2000 µg/L
1/2 SYR4 2013–2019
Fluoride
509 µg/L 13%
of the EPA limit 4000 µg/L
1/2 SYR4 2013–2019
Gross Alpha, Excl. Radon And U
4.03 pCi/L 27%
of the EPA limit 15 pCi/L
1/3 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
8.85 µg/L 15%
of the EPA limit 60 µg/L
1/3 SYR4 2014–2019
63 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNitrateNitrate-NitriteNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
CLAYTON CREEK MH ESTATES
Phone
541-601-6355
Email
[email protected]

Frequently asked questions about Clayton Creek Mh Estates

Is Clayton Creek Mh Estates tap water safe to drink?

EPA monitoring detected 9 contaminants in Clayton Creek Mh Estates's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Clayton Creek Mh Estates's water?

EPA monitoring detected Copper, Lead, Lead, Combined Radium (-226 And -228), TTHM, and others. The full list with the level and data source for each is above.

How many people does Clayton Creek Mh Estates serve?

Clayton Creek Mh Estates reports serving 165 people in Oregon, per its EPA record.

Has Clayton Creek Mh Estates had any water quality violations?

The EPA has 27 violations on file for Clayton Creek Mh Estates, of which 1 is health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.