← Oklahoma

Tap water quality report

Manitou

EPA monitoring tested this supplier for 14 contaminants and detected 14. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

14
contaminants tested
14
detected
278
people served
120
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Tillman

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

120
health-based violations
211
violations on file
2
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
MCL Health-based Archived 2024-01-01 → 2024-03-31
MCL Health-based Archived 2024-01-01 → 2024-03-31
MCL Health-based Archived 2024-01-01 → 2024-03-31
MCL Health-based Archived 2023-10-01 → 2023-12-31
MCL Health-based Archived 2023-10-01 → 2023-12-31
MCL Health-based Archived 2023-10-01 → 2023-12-31
MCL Health-based Archived 2023-07-01 → 2023-09-30
MCL Health-based Archived 2023-07-01 → 2023-09-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
57.22 µg/L 4.4%
of the EPA limit 1300 µg/L
worst single sample: 147 µg/L
25/25 SYR4 2015–2019
Bromodichloromethane
30.135 µg/L
No EPA limit set
worst single sample: 32.7 µg/L
20/20 SYR4 2014–2019
Bromoform
101.115 µg/L
No EPA limit set
worst single sample: 166 µg/L
20/20 SYR4 2014–2019
Dibromoacetic Acid
29.83 µg/L
No EPA limit set
worst single sample: 30.4 µg/L
20/20 SYR4 2014–2019
Dibromochloromethane
77.74 µg/L
No EPA limit set
worst single sample: 107 µg/L
20/20 SYR4 2014–2019
TTHM
202.47 µg/L 253%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 312.1 µg/L
20/20 SYR4 2014–2019
Total Haloacetic Acids (HAA5)
33.9295 µg/L 57%
of the EPA limit 60 µg/L
worst single sample: 45.89 µg/L
20/20 SYR4 2014–2019
Chloroform
22.08 µg/L
No EPA limit set
worst single sample: 31.8 µg/L
13/20 SYR4 2014–2019
Lead
13.302 µg/L 89%
of the EPA limit 15 µg/L
worst single sample: 20.7 µg/L
10/25 SYR4 2015–2019
Dichloroacetic Acid
20.59 µg/L
No EPA limit set
worst single sample: 26.4 µg/L
8/20 SYR4 2014–2019
Monobromoacetic Acid
5.52 µg/L
No EPA limit set
worst single sample: 5.8 µg/L
8/20 SYR4 2014–2019
Lead
0.0011 mg/L 7.1%
of the EPA limit 0.0150 mg/L
6/6 LCR 2025
Monochloroacetic Acid
2.095 µg/L
No EPA limit set
worst single sample: 2.1 µg/L
2/19 SYR4 2014–2019
Trichloroacetic Acid
11.865 µg/L
No EPA limit set
worst single sample: 12.3 µg/L
2/20 SYR4 2014–2019

Utility contact

Contact
MANITOU
Phone
580-397-2006
Email
[email protected]

Frequently asked questions about Manitou

Is Manitou tap water safe to drink?

EPA monitoring detected 14 contaminants in Manitou's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Manitou's water?

EPA monitoring detected Copper, Bromodichloromethane, Bromoform, Dibromoacetic Acid, Dibromochloromethane, and others. The full list with the level and data source for each is above.

How many people does Manitou serve?

Manitou reports serving 278 people in Oklahoma, per its EPA record.

Has Manitou had any water quality violations?

The EPA has 211 violations on file for Manitou, of which 120 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.