Tap water quality report

Yale

EPA monitoring tested this supplier for 14 contaminants and detected 14. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

14
contaminants tested
14
detected
1,227
people served
253
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Payne

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

253
health-based violations
428
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2024-10-17
MCL Health-based Resolved 2022-01-01 → 2022-03-31
MCL Health-based Resolved 2022-01-01 → 2022-03-31
MCL Health-based Resolved 2022-01-01 → 2022-03-31
MCL Health-based Resolved 2022-01-01 → 2022-03-31
MCL Health-based Resolved 2022-01-01 → 2022-03-31
MCL Health-based Resolved 2022-01-01 → 2022-03-31
MCL Health-based Resolved 2022-01-01 → 2022-03-31
MCL Health-based Resolved 2022-01-01 → 2022-03-31
MCL Health-based Resolved 2022-01-01 → 2022-03-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
290 µg/L 22%
of the EPA limit 1300 µg/L
worst single sample: 940 µg/L
161/228 SYR4 2014–2019
TTHM
169.3 µg/L 212%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 195 µg/L
55/55 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
87.435 µg/L 146%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 108 µg/L
52/55 SYR4 2013–2019
Bromodichloromethane
41.82 µg/L
No EPA limit set
worst single sample: 43.5 µg/L
45/45 SYR4 2013–2019
Chloroform
137 µg/L
No EPA limit set
worst single sample: 153 µg/L
45/45 SYR4 2013–2019
Dibromochloromethane
19.4 µg/L
No EPA limit set
worst single sample: 23.4 µg/L
45/45 SYR4 2013–2019
Dichloroacetic Acid
45.3 µg/L
No EPA limit set
worst single sample: 57.7 µg/L
41/45 SYR4 2013–2019
Trichloroacetic Acid
33.6 µg/L
No EPA limit set
worst single sample: 44.8 µg/L
41/45 SYR4 2013–2019
Lead
178.8 µg/L 1192%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 229 µg/L
33/228 SYR4 2014–2019
Dibromoacetic Acid
5.36 µg/L
No EPA limit set
worst single sample: 6.44 µg/L
26/45 SYR4 2013–2019
Lead
0.0067 mg/L 45%
of the EPA limit 0.0150 mg/L
21/21 LCR 2025
Bromoform
3.05 µg/L
No EPA limit set
worst single sample: 4.73 µg/L
17/45 SYR4 2013–2019
Monobromoacetic Acid
1.776 µg/L
No EPA limit set
worst single sample: 1.8 µg/L
9/45 SYR4 2013–2019
Monochloroacetic Acid
8.883 µg/L
No EPA limit set
worst single sample: 9.33 µg/L
7/45 SYR4 2013–2019

Utility contact

Contact
YALE
Phone
918-387-2405
Email
[email protected]

Frequently asked questions about Yale

Is Yale tap water safe to drink?

EPA monitoring detected 14 contaminants in Yale's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Yale's water?

EPA monitoring detected Copper, TTHM, Total Haloacetic Acids (HAA5), Bromodichloromethane, Chloroform, and others. The full list with the level and data source for each is above.

How many people does Yale serve?

Yale reports serving 1,227 people in Oklahoma, per its EPA record.

Has Yale had any water quality violations?

The EPA has 428 violations on file for Yale, of which 253 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.