Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| TT | Health-based | Addressed | 2024-10-17 |
| TT | Health-based | Addressed | 2024-10-17 |
| MCL | Health-based | Resolved | 2016-01-01 → 2016-03-31 |
| MCL | Health-based | Resolved | 2016-01-01 → 2016-03-31 |
| MCL | Health-based | Resolved | 2016-01-01 → 2016-03-31 |
| MCL | Health-based | Resolved | 2016-01-01 → 2016-03-31 |
| MCL | Health-based | Resolved | 2015-10-01 → 2015-12-31 |
| MCL | Health-based | Resolved | 2015-10-01 → 2015-12-31 |
| MCL | Health-based | Resolved | 2015-10-01 → 2015-12-31 |
| MCL | Health-based | Resolved | 2015-10-01 → 2015-12-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate-Nitrite | 11150 µg/L 112% of the EPA limit, at the 95th percentile of samples — 10000 µg/L
worst single sample: 12800 µg/L | 16/16 | SYR4 | 2012–2019 |
| Arsenic | 9.9 µg/L 99% of the EPA limit 10 µg/L
worst single sample: 11.1 µg/L | 13/13 | SYR4 | 2012–2017 |
| Bromoform | 4.12 µg/L No EPA limit set
worst single sample: 4.3 µg/L | 10/13 | SYR4 | 2012–2019 |
| Dibromochloromethane | 3.22 µg/L No EPA limit set
worst single sample: 3.4 µg/L | 10/14 | SYR4 | 2012–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 9/9 | LCR | 2023 |
| Chloroform | 3.67 µg/L No EPA limit set
worst single sample: 3.7 µg/L | 7/14 | SYR4 | 2012–2019 |
| Bromodichloromethane | 1.38 µg/L No EPA limit set
worst single sample: 1.4 µg/L | 5/14 | SYR4 | 2012–2019 |
| Barium | 638.3 µg/L 32% of the EPA limit 2000 µg/L
worst single sample: 677 µg/L | 4/4 | SYR4 | 2012–2018 |
| Carbon Tetrachloride | 2.125 µg/L 43% of the EPA limit 5 µg/L
worst single sample: 2.2 µg/L | 4/23 | SYR4 | 2012–2019 |
| Fluoride | 385.5 µg/L 9.6% of the EPA limit 4000 µg/L
worst single sample: 390 µg/L | 4/4 | SYR4 | 2012–2018 |
| Copper | 19.6515 µg/L 1.5% of the EPA limit 1300 µg/L
worst single sample: 20.4 µg/L | 2/20 | SYR4 | 2012–2017 |
| Dibromoacetic Acid | 1.87 µg/L No EPA limit set
worst single sample: 1.9 µg/L | 2/3 | SYR4 | 2014–2018 |
| Dichloroacetic Acid | 22.76 µg/L No EPA limit set
worst single sample: 23.8 µg/L | 2/3 | SYR4 | 2014–2018 |
| Nitrate | 9050 µg/L 91% of the EPA limit 10000 µg/L | 2/2 | SYR4 | 2012 |
| TTHM | 11.08 µg/L 14% of the EPA limit 80 µg/L
worst single sample: 11.5 µg/L | 2/3 | SYR4 | 2014–2018 |
| Total Haloacetic Acids (HAA5) | 43.055 µg/L 72% of the EPA limit 60 µg/L
worst single sample: 45 µg/L | 2/3 | SYR4 | 2014–2018 |
| Trichloroacetic Acid | 18.425 µg/L No EPA limit set
worst single sample: 19.3 µg/L | 2/3 | SYR4 | 2014–2018 |
| Combined Uranium | 2.2 µg/L 7.3% of the EPA limit 30 µg/L | 1/1 | SYR4 | 2018 |
| Gross Alpha, Excl. Radon And U | 1.9 pCi/L 13% of the EPA limit 15 pCi/L | 1/1 | SYR4 | 2018 |
36 contaminants tested, none detected
Utility contact
Frequently asked questions about Shady Acres Custer County
Is Shady Acres Custer County tap water safe to drink?
EPA monitoring detected 19 contaminants in Shady Acres Custer County's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Shady Acres Custer County's water?
EPA monitoring detected Nitrate-Nitrite, Arsenic, Bromoform, Dibromochloromethane, Lead, and others. The full list with the level and data source for each is above.
How many people does Shady Acres Custer County serve?
Shady Acres Custer County reports serving 40 people in Oklahoma, per its EPA record.
Has Shady Acres Custer County had any water quality violations?
The EPA has 973 violations on file for Shady Acres Custer County, of which 25 are health-based (a contaminant limit or required treatment was breached) and 10 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.