← Oklahoma

Tap water quality report

Wynnewood Water & Light

EPA monitoring tested this supplier for 65 contaminants and detected 15. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

65
contaminants tested
15
detected
2,307
people served
197
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Garvin

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

197
health-based violations
357
violations on file
1
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2024-10-17
MCL Health-based Resolved 2017-01-01 → 2017-03-31
MCL Health-based Resolved 2017-01-01 → 2017-03-31
MCL Health-based Resolved 2017-01-01 → 2017-03-31
MCL Health-based Resolved 2017-01-01 → 2017-03-31
MCL Health-based Resolved 2017-01-01 → 2017-03-31
MCL Health-based Resolved 2016-10-01 → 2016-12-31
MCL Health-based Resolved 2016-10-01 → 2016-12-31
MCL Health-based Resolved 2016-10-01 → 2016-12-31
MCL Health-based Resolved 2016-10-01 → 2016-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
31.32 µg/L
No EPA limit set
worst single sample: 42.5 µg/L
57/57 SYR4 2012–2019
Chloroform
100.16 µg/L
No EPA limit set
worst single sample: 145 µg/L
57/57 SYR4 2012–2019
Dibromochloromethane
24.44 µg/L
No EPA limit set
worst single sample: 28.6 µg/L
57/57 SYR4 2012–2019
TTHM
128.16 µg/L 160%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 178.9 µg/L
57/57 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
73.05 µg/L 122%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 120.1 µg/L
56/57 SYR4 2012–2019
Dichloroacetic Acid
29.26 µg/L
No EPA limit set
worst single sample: 48 µg/L
55/57 SYR4 2012–2019
Trichloroacetic Acid
46.21 µg/L
No EPA limit set
worst single sample: 67.1 µg/L
52/57 SYR4 2012–2019
Copper
889.636 µg/L 68%
of the EPA limit 1300 µg/L
worst single sample: 1555.46 µg/L
30/30 SYR4 2013–2019
Bromoform
8.652 µg/L
No EPA limit set
worst single sample: 14.8 µg/L
27/57 SYR4 2012–2019
Lead
5.75 µg/L 38%
of the EPA limit 15 µg/L
worst single sample: 12.6 µg/L
21/30 SYR4 2013–2019
Nitrate-Nitrite
450 µg/L 4.5%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Dibromoacetic Acid
7.657 µg/L
No EPA limit set
worst single sample: 8.71 µg/L
14/57 SYR4 2012–2019
Monochloroacetic Acid
4.0445 µg/L
No EPA limit set
worst single sample: 5 µg/L
14/57 SYR4 2012–2019
Lead
0.0012 mg/L 7.9%
of the EPA limit 0.0150 mg/L
12/12 LCR 2025
Monobromoacetic Acid
9.543 µg/L
No EPA limit set
worst single sample: 10.2 µg/L
4/57 SYR4 2012–2019
50 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAtrazineBhc-GammaBenzeneBenzo(A)PyreneChlorobenzeneCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMethoxychlorOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
WYNNEWOOD WATER & LIGHT
Phone
405-665-2301
Email
[email protected]

Frequently asked questions about Wynnewood Water & Light

Is Wynnewood Water & Light tap water safe to drink?

EPA monitoring detected 15 contaminants in Wynnewood Water & Light's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Wynnewood Water & Light's water?

EPA monitoring detected Bromodichloromethane, Chloroform, Dibromochloromethane, TTHM, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.

How many people does Wynnewood Water & Light serve?

Wynnewood Water & Light reports serving 2,307 people in Oklahoma, per its EPA record.

Has Wynnewood Water & Light had any water quality violations?

The EPA has 357 violations on file for Wynnewood Water & Light, of which 197 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.