Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| Other | Monitoring | Unaddressed | 2026-01-28 |
| MR | Monitoring | Resolved | 2012-09-20 |
| MR | Monitoring | Resolved | 2012-09-20 |
| MR | Monitoring | Resolved | 2012-09-20 |
| MR | Monitoring | Resolved | 2011-10-01 |
| MR | Monitoring | Resolved | 2011-10-01 |
| MR | Monitoring | Resolved | 2011-10-01 |
| MR | Monitoring | Resolved | 2011-10-01 |
| MR | Monitoring | Resolved | 2011-01-01 → 2011-12-31 |
| MR | Monitoring | Resolved | 2011-01-01 → 2011-12-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 246.45 µg/L 19% of the EPA limit 1300 µg/L
worst single sample: 319 µg/L | 60/60 | SYR4 | 2012–2018 |
| Lead | 7.22 µg/L 48% of the EPA limit 15 µg/L
worst single sample: 7.6 µg/L | 20/60 | SYR4 | 2012–2018 |
| Lead | 0.0048 mg/L 32% of the EPA limit 0.0150 mg/L | 19/19 | LCR | 2024 |
| Chloroform | 1.768 µg/L No EPA limit set
worst single sample: 2.11 µg/L | 13/17 | SYR4 | 2013–2019 |
| TTHM | 6.242 µg/L 7.8% of the EPA limit 80 µg/L
worst single sample: 8.09 µg/L | 13/14 | SYR4 | 2013–2019 |
| Bromodichloromethane | 2.083 µg/L No EPA limit set
worst single sample: 2.37 µg/L | 8/17 | SYR4 | 2013–2019 |
| Dibromochloromethane | 2.103 µg/L No EPA limit set
worst single sample: 2.53 µg/L | 8/17 | SYR4 | 2013–2019 |
| Total Haloacetic Acids (HAA5) | 15.354 µg/L 26% of the EPA limit 60 µg/L
worst single sample: 18.3 µg/L | 5/14 | SYR4 | 2013–2019 |
| Barium | 206.7 µg/L 10% of the EPA limit 2000 µg/L
worst single sample: 209 µg/L | 3/3 | SYR4 | 2013–2019 |
| Trichloroacetic Acid | 3.168 µg/L No EPA limit set
worst single sample: 3.39 µg/L | 3/14 | SYR4 | 2013–2019 |
| Bromoform | 1.0565 µg/L No EPA limit set
worst single sample: 1.08 µg/L | 2/17 | SYR4 | 2013–2019 |
| Dichloroacetic Acid | 14.215 µg/L No EPA limit set
worst single sample: 14.9 µg/L | 2/14 | SYR4 | 2013–2019 |
| Monochloroacetic Acid | 1.7955 µg/L No EPA limit set
worst single sample: 1.83 µg/L | 2/14 | SYR4 | 2013–2019 |
| Chromium | 4.11 µg/L 4.1% of the EPA limit 100 µg/L | 1/3 | SYR4 | 2013–2019 |
| Dibromoacetic Acid | 1.2 µg/L No EPA limit set | 1/14 | SYR4 | 2013–2019 |
68 contaminants tested, none detected
Utility contact
Frequently asked questions about Minerva Village
Is Minerva Village tap water safe to drink?
EPA monitoring detected 15 contaminants in Minerva Village's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Minerva Village's water?
EPA monitoring detected Copper, Lead, Lead, Chloroform, TTHM, and others. The full list with the level and data source for each is above.
How many people does Minerva Village serve?
Minerva Village reports serving 3,684 people in Ohio, per its EPA record.
Has Minerva Village had any water quality violations?
The EPA has 102 violations on file for Minerva Village, of which 0 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.