Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| Other | Monitoring | Unaddressed | 2025-12-30 |
| Other | Monitoring | Resolved | 2025-11-19 |
| Other | Monitoring | Resolved | 2025-11-19 |
| Other | Monitoring | Unaddressed | 2024-08-01 |
| MR | Monitoring | Resolved | 2024-01-01 → 2024-12-31 |
| MR | Monitoring | Resolved | 2024-01-01 → 2024-12-31 |
| MR | Monitoring | Resolved | 2024-01-01 → 2024-12-31 |
| MR | Monitoring | Resolved | 2024-01-01 → 2024-12-31 |
| MR | Monitoring | Resolved | 2024-01-01 → 2024-12-31 |
| MR | Monitoring | Resolved | 2024-01-01 → 2024-12-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Lead | 0.0016 mg/L 11% of the EPA limit 0.0150 mg/L | 29/29 | LCR | 2025 |
| Nitrate | 2700 µg/L 27% of the EPA limit 10000 µg/L | 16/16 | SYR4 | 2012–2019 |
| Copper | 431 µg/L 33% of the EPA limit 1300 µg/L
worst single sample: 550 µg/L | 15/25 | SYR4 | 2012–2019 |
| Bromodichloromethane | 10.455 µg/L No EPA limit set
worst single sample: 10.5 µg/L | 10/10 | SYR4 | 2013–2019 |
| Bromoform | 2.743 µg/L No EPA limit set
worst single sample: 3.04 µg/L | 10/10 | SYR4 | 2013–2019 |
| Chloroform | 14.33 µg/L No EPA limit set
worst single sample: 14.6 µg/L | 10/10 | SYR4 | 2013–2019 |
| Dibromochloromethane | 6.9955 µg/L No EPA limit set
worst single sample: 7.18 µg/L | 10/10 | SYR4 | 2013–2019 |
| Dichloroacetic Acid | 7.528 µg/L No EPA limit set
worst single sample: 8.08 µg/L | 7/7 | SYR4 | 2013–2019 |
| TTHM | 32.882 µg/L 41% of the EPA limit 80 µg/L
worst single sample: 32.99 µg/L | 7/7 | SYR4 | 2013–2019 |
| Trichloroacetic Acid | 4.02 µg/L No EPA limit set
worst single sample: 4.29 µg/L | 7/7 | SYR4 | 2013–2019 |
| Dibromoacetic Acid | 2.305 µg/L No EPA limit set
worst single sample: 2.34 µg/L | 6/7 | SYR4 | 2013–2019 |
| Nitrate-Nitrite | 2670 µg/L 27% of the EPA limit 10000 µg/L
worst single sample: 2700 µg/L | 5/5 | SYR4 | 2012–2016 |
| Total Haloacetic Acids (HAA5) | 12.944 µg/L 22% of the EPA limit 60 µg/L
worst single sample: 13.66 µg/L | 5/7 | SYR4 | 2013–2019 |
| Lead | 10.696 µg/L 71% of the EPA limit 15 µg/L
worst single sample: 10.86 µg/L | 3/24 | SYR4 | 2012–2019 |
| Fluoride | 230 µg/L 5.8% of the EPA limit 4000 µg/L | 1/3 | SYR4 | 2013–2019 |
| Nitrite | 100 µg/L 10% of the EPA limit 1000 µg/L | 1/1 | SYR4 | 2013 |
36 contaminants tested, none detected
Utility contact
Frequently asked questions about Fair Haven Shelby County Home
Is Fair Haven Shelby County Home tap water safe to drink?
EPA monitoring detected 16 contaminants in Fair Haven Shelby County Home's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Fair Haven Shelby County Home's water?
EPA monitoring detected Lead, Nitrate, Copper, Bromodichloromethane, Bromoform, and others. The full list with the level and data source for each is above.
How many people does Fair Haven Shelby County Home serve?
Fair Haven Shelby County Home reports serving 290 people in Ohio, per its EPA record.
Has Fair Haven Shelby County Home had any water quality violations?
The EPA has 47 violations on file for Fair Haven Shelby County Home, of which 0 are health-based (a contaminant limit or required treatment was breached) and 5 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.