← Ohio

Tap water quality report

Clyde City

EPA monitoring tested this supplier for 83 contaminants and detected 20. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

83
contaminants tested
20
detected
6,325
people served
0
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Sandusky

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
21
violations on file
2
still open
ViolationTypeStatusPeriod
Other Monitoring Unaddressed 2024-02-02
Other Monitoring Unaddressed 2019-01-10
Other Monitoring Resolved 2004-07-01
Other Monitoring Resolved 2004-07-01
Other Monitoring Resolved 2001-07-01
Other Monitoring Resolved 2001-07-01
MR Monitoring Resolved 2000-06-01 → 2000-06-30
MR Monitoring Resolved 2000-06-01 → 2000-06-30
MR Monitoring Resolved 2000-06-01 → 2000-06-30
MR Monitoring Resolved 2000-06-01 → 2000-06-30

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
Pfba 0.0064 µg/L 2/3 2025

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
710 µg/L 7.1%
of the EPA limit 10000 µg/L
worst single sample: 831 µg/L
132/190 SYR4 2012–2019
Dichloroacetic Acid
25.33 µg/L
No EPA limit set
worst single sample: 31.7 µg/L
68/69 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
32.65 µg/L 54%
of the EPA limit 60 µg/L
worst single sample: 39 µg/L
68/69 SYR4 2012–2019
Trichloroacetic Acid
5.73 µg/L
No EPA limit set
worst single sample: 7 µg/L
67/68 SYR4 2012–2019
Nitrate-Nitrite
697.5 µg/L 7%
of the EPA limit 10000 µg/L
worst single sample: 830 µg/L
66/96 SYR4 2012–2019
Bromodichloromethane
9.248 µg/L
No EPA limit set
worst single sample: 10.2 µg/L
64/65 SYR4 2012–2019
Chloroform
73.565 µg/L
No EPA limit set
worst single sample: 81.8 µg/L
64/65 SYR4 2012–2019
TTHM
82.84 µg/L 104%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 92.7 µg/L
64/65 SYR4 2012–2019
Dibromochloromethane
2.017 µg/L
No EPA limit set
worst single sample: 2.48 µg/L
62/63 SYR4 2012–2019
Copper
54.15 µg/L 4.2%
of the EPA limit 1300 µg/L
worst single sample: 59 µg/L
40/48 SYR4 2014–2019
Atrazine
0.6210 µg/L 21%
of the EPA limit 3 µg/L
worst single sample: 0.6400 µg/L
20/24 SYR4 2012–2019
Monochloroacetic Acid
4.865 µg/L
No EPA limit set
worst single sample: 6.1 µg/L
20/69 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
17/17 LCR 2023
Fluoride
1063 µg/L 27%
of the EPA limit 4000 µg/L
worst single sample: 1070 µg/L
8/8 SYR4 2012–2019
Bromoform
0.5200 µg/L
No EPA limit set
2/65 SYR4 2012–2019
Lead
19.415 µg/L 129%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 20 µg/L
2/40 SYR4 2014–2017
Dibromoacetic Acid
1.1 µg/L
No EPA limit set
1/66 SYR4 2012–2019
Nitrite
110 µg/L 11%
of the EPA limit 1000 µg/L
1/75 SYR4 2012–2018
Simazine
0.3500 µg/L 8.8%
of the EPA limit 4 µg/L
1/24 SYR4 2012–2019
63 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAsbestosBariumBenzeneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbon TetrachlorideChromiumDichloromethaneEthylbenzeneHfpo-DaLassoMercuryMonobromoacetic AcidNetfosaaNfdhaNmefosaaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaSeleniumStyreneTetrachloroethyleneThallium, TotalTolueneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
FARRAR, PHILLIP
Phone
419-547-9805
Email
[email protected]

Frequently asked questions about Clyde City

Is Clyde City tap water safe to drink?

EPA monitoring detected 20 contaminants in Clyde City's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Clyde City's water?

EPA monitoring detected Nitrate, Dichloroacetic Acid, Total Haloacetic Acids (HAA5), Trichloroacetic Acid, Nitrate-Nitrite, and others. The full list with the level and data source for each is above.

How many people does Clyde City serve?

Clyde City reports serving 6,325 people in Ohio, per its EPA record.

Has Clyde City had any water quality violations?

The EPA has 21 violations on file for Clyde City, of which 0 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.