← Ohio

Tap water quality report

Eaton Public Water

EPA monitoring tested this supplier for 84 contaminants and detected 20. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

84
contaminants tested
20
detected
8,400
people served
0
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Preble

Compliance record

No violations on file. The EPA has no formal drinking-water violations recorded for this supplier.

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
519.55 µg/L 40%
of the EPA limit 1300 µg/L
worst single sample: 949 µg/L
102/103 SYR4 2012–2019
Lead
12.28 µg/L 82%
of the EPA limit 15 µg/L
worst single sample: 43 µg/L
52/103 SYR4 2012–2019
Lead
0.0079 mg/L 53%
of the EPA limit 0.0150 mg/L
28/28 LCR 2025
Bromodichloromethane
7.8615 µg/L
No EPA limit set
worst single sample: 10.3 µg/L
22/24 SYR4 2013–2019
Chloroform
13.806 µg/L
No EPA limit set
worst single sample: 29.6 µg/L
22/24 SYR4 2013–2019
Dibromochloromethane
6.766 µg/L
No EPA limit set
worst single sample: 7.12 µg/L
22/24 SYR4 2013–2019
Nitrate
442 µg/L 4.4%
of the EPA limit 10000 µg/L
18/32 SYR4 2012–2019
Dichloroacetic Acid
4.5135 µg/L
No EPA limit set
worst single sample: 4.8 µg/L
16/16 SYR4 2013–2019
TTHM
31.125 µg/L 39%
of the EPA limit 80 µg/L
worst single sample: 45.6 µg/L
16/16 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
8.7355 µg/L 15%
of the EPA limit 60 µg/L
worst single sample: 8.824 µg/L
16/16 SYR4 2013–2019
Trichloroacetic Acid
3.802 µg/L
No EPA limit set
worst single sample: 4.288 µg/L
16/16 SYR4 2013–2019
Bromoform
1.99 µg/L
No EPA limit set
worst single sample: 2.1 µg/L
12/24 SYR4 2013–2019
Dibromoacetic Acid
2.2839 µg/L
No EPA limit set
worst single sample: 2.349 µg/L
8/16 SYR4 2013–2019
Barium
258.25 µg/L 13%
of the EPA limit 2000 µg/L
worst single sample: 261 µg/L
6/6 SYR4 2013–2019
Fluoride
1167.5 µg/L 29%
of the EPA limit 4000 µg/L
worst single sample: 1180 µg/L
6/6 SYR4 2013–2019
Arsenic
3.918 µg/L 39%
of the EPA limit 10 µg/L
worst single sample: 3.92 µg/L
3/6 SYR4 2013–2019
Nitrate-Nitrite
318.3 µg/L 3.2%
of the EPA limit 10000 µg/L
worst single sample: 323 µg/L
3/4 SYR4 2012–2013
P-Dichlorobenzene
0.9285 µg/L 1.2%
of the EPA limit 75 µg/L
worst single sample: 0.9500 µg/L
2/8 SYR4 2013–2019
Cadmium
0.2400 µg/L 4.8%
of the EPA limit 5 µg/L
1/6 SYR4 2013–2019
Thallium, Total
1.3 µg/L 65%
of the EPA limit 2 µg/L
1/6 SYR4 2013–2019
64 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAsbestosAtrazineBenzeneBeryllium, TotalChlorobenzeneCyanideCarbon TetrachlorideChromiumDichloromethaneEthylbenzeneHfpo-DaLassoMercuryMonobromoacetic AcidMonochloroacetic AcidNetfosaaNfdhaNmefosaaNitritePfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaSeleniumSimazineStyreneTetrachloroethyleneTolueneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
DENLINGER, CHRIS A.
Phone
937-456-4125
Email
[email protected]

Frequently asked questions about Eaton Public Water

Is Eaton Public Water tap water safe to drink?

EPA monitoring detected 20 contaminants in Eaton Public Water's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Eaton Public Water's water?

EPA monitoring detected Copper, Lead, Lead, Bromodichloromethane, Chloroform, and others. The full list with the level and data source for each is above.

How many people does Eaton Public Water serve?

Eaton Public Water reports serving 8,400 people in Ohio, per its EPA record.

Has Eaton Public Water had any water quality violations?

The EPA has no formal drinking-water violations on file for Eaton Public Water.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.