Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2007-08-01 → 2007-08-31 |
| MR | Monitoring | Resolved | 2008-07-01 → 2008-07-31 |
| MR | Monitoring | Resolved | 2008-07-01 → 2008-07-31 |
| MR | Monitoring | Resolved | 2008-07-01 → 2008-07-31 |
| MR | Monitoring | Resolved | 2002-06-01 → 2002-06-30 |
| MR | Monitoring | Resolved | 2002-06-01 → 2002-06-30 |
| MR | Monitoring | Resolved | 2002-06-01 → 2002-06-30 |
| MR | Monitoring | Resolved | 2002-06-01 → 2002-06-30 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 316 µg/L 24% of the EPA limit 1300 µg/L
worst single sample: 780 µg/L | 230/241 | SYR4 | 2013–2019 |
| Bromodichloromethane | 26.265 µg/L No EPA limit set
worst single sample: 29.92 µg/L | 116/116 | SYR4 | 2012–2019 |
| Bromoform | 10.675 µg/L No EPA limit set
worst single sample: 14.88 µg/L | 116/116 | SYR4 | 2012–2019 |
| Chloroform | 27.5725 µg/L No EPA limit set
worst single sample: 39.4 µg/L | 116/116 | SYR4 | 2012–2019 |
| Dibromochloromethane | 25.225 µg/L No EPA limit set
worst single sample: 31.07 µg/L | 116/116 | SYR4 | 2012–2019 |
| TTHM | 83.2325 µg/L 104% of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 99.6 µg/L | 116/116 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 8.3162 µg/L No EPA limit set
worst single sample: 8.972 µg/L | 115/115 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 19.123 µg/L 32% of the EPA limit 60 µg/L
worst single sample: 20.21 µg/L | 115/115 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 5.4714 µg/L No EPA limit set
worst single sample: 6.6 µg/L | 114/115 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 8.1 µg/L No EPA limit set
worst single sample: 8.8 µg/L | 109/115 | SYR4 | 2012–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 25/25 | LCR | 2025 |
| Lead | 16.8 µg/L 112% of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 18 µg/L | 11/240 | SYR4 | 2013–2019 |
| Monochloroacetic Acid | 8.4145 µg/L No EPA limit set
worst single sample: 8.734 µg/L | 11/115 | SYR4 | 2012–2019 |
| Monobromoacetic Acid | 1 µg/L No EPA limit set | 1/115 | SYR4 | 2012–2019 |
30 contaminants tested, none detected
Utility contact
Frequently asked questions about Streetsboro City
Is Streetsboro City tap water safe to drink?
EPA monitoring detected 14 contaminants in Streetsboro City's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Streetsboro City's water?
EPA monitoring detected Copper, Bromodichloromethane, Bromoform, Chloroform, Dibromochloromethane, and others. The full list with the level and data source for each is above.
How many people does Streetsboro City serve?
Streetsboro City reports serving 15,105 people in Ohio, per its EPA record.
Has Streetsboro City had any water quality violations?
The EPA has 8 violations on file for Streetsboro City, of which 1 is health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.