Tap water quality report

Portersville East Branch Water Co.

EPA monitoring tested this supplier for 14 contaminants and detected 13. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

14
contaminants tested
13
detected
2,340
people served
77
health-based violations
Water source
GWP
Ownership
Local government
Counties served
Perry

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

77
health-based violations
88
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2008-04-01 → 2008-06-30
MCL Health-based Resolved 2008-04-01 → 2008-06-30
MCL Health-based Resolved 2008-04-01 → 2008-06-30
MCL Health-based Resolved 2008-04-01 → 2008-06-30
MCL Health-based Resolved 2008-01-01 → 2008-03-31
MCL Health-based Resolved 2008-01-01 → 2008-03-31
MCL Health-based Resolved 2008-01-01 → 2008-03-31
MCL Health-based Resolved 2008-01-01 → 2008-03-31
MCL Health-based Resolved 2008-01-01 → 2008-03-31
MCL Health-based Resolved 2007-10-01 → 2007-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
310.55 µg/L 24%
of the EPA limit 1300 µg/L
worst single sample: 392 µg/L
64/80 SYR4 2012–2018
Lead
0.0043 mg/L 29%
of the EPA limit 0.0150 mg/L
20/20 LCR 2024
Bromoform
4.01 µg/L
No EPA limit set
worst single sample: 4.5 µg/L
15/15 SYR4 2012–2019
Chloroform
29.36 µg/L
No EPA limit set
worst single sample: 36.5 µg/L
15/15 SYR4 2012–2019
Dibromoacetic Acid
5.39 µg/L
No EPA limit set
worst single sample: 5.6 µg/L
15/15 SYR4 2012–2019
Dibromochloromethane
16.85 µg/L
No EPA limit set
worst single sample: 17.2 µg/L
15/15 SYR4 2012–2019
Dichloroacetic Acid
11.46 µg/L
No EPA limit set
worst single sample: 15.1 µg/L
15/15 SYR4 2012–2019
TTHM
64.31 µg/L 80%
of the EPA limit 80 µg/L
worst single sample: 64.8 µg/L
15/15 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
24.05 µg/L 40%
of the EPA limit 60 µg/L
worst single sample: 32.8 µg/L
15/15 SYR4 2012–2019
Trichloroacetic Acid
7.86 µg/L
No EPA limit set
worst single sample: 10.8 µg/L
15/15 SYR4 2012–2019
Bromodichloromethane
21.705 µg/L
No EPA limit set
worst single sample: 21.9 µg/L
14/14 SYR4 2013–2019
Lead
5.863 µg/L 39%
of the EPA limit 15 µg/L
worst single sample: 5.98 µg/L
4/80 SYR4 2012–2018
Monochloroacetic Acid
4.1 µg/L
No EPA limit set
1/15 SYR4 2012–2019
1 contaminants tested, none detected
Monobromoacetic Acid

Utility contact

Contact
MONTGOMERY, JAMES
Phone
740-342-1290
Email
[email protected]

Frequently asked questions about Portersville East Branch Water Co.

Is Portersville East Branch Water Co. tap water safe to drink?

EPA monitoring detected 13 contaminants in Portersville East Branch Water Co.'s water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Portersville East Branch Water Co.'s water?

EPA monitoring detected Copper, Lead, Bromoform, Chloroform, Dibromoacetic Acid, and others. The full list with the level and data source for each is above.

How many people does Portersville East Branch Water Co. serve?

Portersville East Branch Water Co. reports serving 2,340 people in Ohio, per its EPA record.

Has Portersville East Branch Water Co. had any water quality violations?

The EPA has 88 violations on file for Portersville East Branch Water Co., of which 77 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.